Deutsch  English 


screw-in transmitter | LABO-D...-I/U/F/C

screw-in transmitter | LABO-D...-I/U/F/C


184,50 EUR

 inkl. 19 % USt  -> Preis zzgl. Versandkosten

Lieferzeit bzw. Fertigungszeit variiert - bitte erfragen!

Art.Nr.: LABO-D-IUFC
sensor:
H: magnetic field sensor:
I: inductive (for flow meter RRI):
V: pre-tensioned hall sensor:
signal output:
C: pulse output:
I: current output 4 mA to 20 mA:
U: voltage output 0 V to 10 V:
F: frequency output:
programming:
N: not programmable (no teach-in):
P: programmable (teach-in possible):
electrical connection:
S: for round connector M12x1, 4-pole:
options for LABO / FLEX:
for LABO/FLEX-...-F: output frequency at full scale (maximum value: 2.000 Hz):
for LABO/FLEX-...-C: input pulse per output pulse (For the pulse output version, the quantity per pulse must be specified, in other words the number of input pulses which should correspond to an output pulse. In the process, uneven scaling factors are als:

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Produktbeschreibung


general information:

The transmitters combine a primary sensor with evaluation electronics with a powerful 16-bit microcontroller in the housing of a proximity switch. The evaluation electronics enable, for example, the speed measurement of rotating machine parts, turbines, spinners, etc. by means of the detection of the approach of metals or magnets in various environments and the evaluation of the resulting frequency.

The primary sensors are available with various technologies depending on the application:

  • magnetic field sensors are capable of detecting the approach of magnets. This is also possible through metallic surfaces.
  • pre-tensioned hall sensors detect the approach of ferromagnetic metal parts, even through metallic but non-ferromagnetic surfaces.
  • inductive sensors detect the approach of all types of metal parts and can therefore not be used behind metal surfaces.

The LABO electronics provide various output signals:

  • analog signal 0/4 mA to 20 mA (LABO-D...I)
  • analog signal 0/2 V to 10 V (LABO-D...U)
  • frequency signal (LABO-D...F) or
  • quantity signal Pulse / x Litres (LABO-D...C).

A model with switching output is also available.

If desired, the range end value can be set to the currently existing frequency using "teach-in".

  • complete sensor with transmitter in the housing of a proximity switch
  • conversion of frequencies into current, voltage, frequency or pulse signals
  • various sensors available
  • 16-bit microcontroller
  • linearisable
  • numerous configurable parameters
  • a parameter can be set locally
  • affordable


specifications:

sensor: - magnetic field sensor (magneto-resistive)
- pre-tensioned hall sensor
- inductive sensor
detection distance: magnetic field sensor:
depending on magnets used, signal threshold typ. 8 Gauss (= 0.8 milliTesla), switching distances over 25 mm possible
pre-tensioned hall sensor:
typ. 0.5 mm to 2.5 mm
inductive sensor:
typ. max. 4 mm based on 1 cm3 ST37

measuring range: 0 kHz to 10 kHz
measurement uncertainty: ±0.1 % measured value
pressure resistance: pressureless application
operating temperature: 0°C to +70°C
(other temperatures available upon request)
storage temperature: -20°C to +80°C
materials:housing: CW614N nickel-plated
sensor flap: PA
plug insert: PC
contacts: CuZn, gold-plated
supply voltage:10 V DC to 30 V DC
with voltage output 10 V: 15 V DC to 30 V DC
power consumption:<1 W (for unloaded output)
output data:all outputs are resistant to short circuits and reversal polarity protected

- current output: 4 mA to 20 mA (0 mA to 20 mA upon request)
- voltage output: 0 V to 10 V (2 V to 10 V upon request), output
  current max. 20 mA
- frequency output: transistor output "push-pull"
lout =
  100 mA max.
- pulse output: transistor output "push-pull"
lout = 100 mA max.
  pulse width 50 ms, pulse/quantity has to be stated in the order
display:yellow LED shows
operating voltage (LABO-D...I / U) or
output status (LABO-D...F / C)
(rapid flashing = programming)
electr. connection:for round plug connector M12x1, 4-pole
ingress protection:IP 67
weight:approx. 0.02 kg
conformity: CE




For further details p.r.t. data sheet:


 

 

 

Empfohlenes Zubehör | Weitere Artikel

Rundsteckverbinder 4-/5-polig | K...PU...

Rundsteckverbinder 4-/5-polig | K...PU...

0,00 EUR

Gerätekonfigurator | ECI-3

Gerätekonfigurator | ECI-3

697,00 EUR

Frequenzschalter | LABO-D...-S

Frequenzschalter | LABO-D...-S

184,00 EUR

Warenkorb

Sie haben noch keine Artikel in Ihrem Warenkorb.

Warenkorb »

Herzlich willkommen

E-Mail-Adresse:
Passwort:
Passwort vergessen?

Top Artikel