Deutsch  English 


portable multisensor measuring device for water analysis | G 7500

portable multisensor measuring device for water analysis | G 7500


825,00 EUR

 inkl. 19 % USt  -> Preis zzgl. Versandkosten

Lieferzeit bzw. Fertigungszeit variiert - bitte erfragen!

Art.Nr.: G 7500
set options:
G 7500: device only (without electrode):
G 7500-PH/O2: device, GE125-L02 + accessories, GWO 5610-L02 + accessories, GKK 2021 (+ 617,00 EUR) :
G 7500-PH/CON: device, GE125-L02 + accessories, LF425-L02 + accessories, GKK 2021 (+ 617,00 EUR) :
G 7500-PH/CON/O2: device, GE125-L02 + accessories, LF425-L02 + accessories, GWO5610-L02 + accessories, GKK 2021 (+ 1.024,00 EUR) :
G 7500-PH/CON/O2_L4: device, GE125-L02 + accessories, LF425-L02 + accessories, GWO5610-L04 + accessories, GKK 2021 (+ 1.043,00 EUR) :

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Produktbeschreibung


general information:

G 7500 is a comfortable multichannel measuring device for water analysis. It measures two parameters and the associated temperature simultaneously. All major electrochemical measurements are combinable:

- pH / ORP + conductivity / salinity
- pH / ORP + dissolved oxygen

The illuminated graphic display indicates all parameters in plain text in German or English, other languages are integrable (charges upon request). Large display or measurement diagrams are also displayable. Our proven standard plug connectors guarantee the use of our standard sensors - intentionally without additional costs due to complex technology  in the sensors. Thus the device convinces with its efficiency and the affordable system price (also note our sets). The modern device platform uses the common USB cables for charging the internal batteries (changeable) and for reading out the data logger without additional software or adapter. The logger is read out comfortably like a USB 2.0 data stick.

  • simultaneous measurement of pH / oxygen or pH / conductivity
    and the associated temperatures
  • integrated galvanic isolation allows simultaneous measuring – with cost-efficient standard sensor technology
  • the display allows comfortable reading of various values simultaneously and of the measurement progression in diagram form
  • the data logger can be read out directly via USB – with standard
    smartphone cable or software
  • simple and comfortable battery charging via USB connection


application:

Therefore applications like water monitoring,
neutralization processes or agricultural measurements are compactly under your control:

  • water monitoring
  • drinking water treatment
  • sewage treatment plants
  • fish farming and aquaculture
  • vertical / urban farming
  • conventional agriculture


set options:

G 7500: portable multisensor measuring device for water analysis.

G 7500-PH/O2:
portable multisensor measuring device for water analysis
device, pH electrode GE125-L02 + accessories, electrode for dissolved oxygen GWO 5610-L02 + accessories, case GKK 2021

G 7500-PH/CON:
portable multisensor measuring device for water analysis
device, pH electrode GE125-L02 + accessories, conductivity measuring cell LF425-L02 + accessories, case GKK 2021

G 7500-PH/CON/O2: portable multisensor measuring device for water analysis
device, pH electrode GE125-L02 + accessories, conductivity measuring cell LF425-L02 + accessories, electrode for dissolved oxygen GWO5610-L02 + accessories, case GKK 2021


specifications:

input no. 1 (pH/ORP)

connection:BNC waterproof
measuring range:                          
-2.00 pH to +16.00 pH (± 0.25 % FS @ 25°C)
or -1,500 mV to +1,500 mV redox voltage
(±0.25 % FS @ 25°C)
temperature:-10.0°C to +150.0°C (Pt1000)
±0.25 % FS connection via 4 mm
banana or
O2/LF sensor
temperature compensation:

manueal, automatic

input no. 2
connection:7-pole bayonet socket
temperature: -10.0°C to +110.0°C (NTC or Pt1000)
measuring range (Pt 1000)
-10.0°C to +110.0°C
measuring range (NTC 10k)
-10.0°C to +110.0°C
(integrated in
O2/LF sensor)
conductivity: measuring range:
0 μS/cm to 500 mS/cm (±0.5 % FS @ 25°C)
salinity/PSU: 0.0 g/kg to 70.0 g/kg
cell constant: 0.3 1/cm to 1.6000 1/cm
temperature compensation:
off, linear (0.300 %/K to 3.000 %/K), NLF (nach DIN EN 27888), reference temperature: 20°C or 25°C (adjustable)
dissolved oxygen:measuring range:
oxygen saturation: 0.0 % to 500.0 % sat
oxygen concentration: 0.0 mg/l to 50.0 mg/l
oxygen partial pressure: 0 mbar
O2 to 1,013 mbar O2
(accuracy depending on sensor and calibration, with flow >20 cm/s, add. ±1.5 % FS @ 25°C, 100 % sat.
O2)
temperature compensation:
automatic via connected sensor
pressure compensation:
manual, automatic via int. sensor: 500 hPa to 1,100 hPa ±4 hPa
salinity compensation:
manual PSU 0 g/kg to 70 g/kg
additional functions:text-based user guidance (DE/EN), Charging via USB socket (3x AAA battery integrated, changeable)
display:LCD (180 x 128 pixel), monochrome, adjustable background illumination
interface:USB 2.0, micro USB socket
calibration:pH 1 to 5 point calibration
(PHL buffer, DIN buffer)
LF cell constant
O2: water-saturated air
data logger:yes (8 GB with FAT file system)
alarm:yes, acoustic alerting (horn)
visual (red LDC background)
power supply:3x NiMh AAA (max. 750 mAh)
power consumption:on: approx. 75 mA in operation;
off: approx. <0.1 mA
housing:impact resistant ABS, integrated pop-up clip
ingress protection:IP67
dimensions:160 x 86 x 37 mm (H x B x T) incl. protection case
weight:300 g incl. battery and protection case






For further details p.r.t. data sheet:







instruction manual as .pdf:


 

 

 

Empfohlenes Zubehör | Weitere Artikel

Leitfähigkeitskontrolllösung | GKL 100

Leitfähigkeitskontrolllösung | GKL 100

9,15 EUR

Leitfähigkeitskontrolllösung | GKL 102

Leitfähigkeitskontrolllösung | GKL 102

9,15 EUR

Ersatz-Elektrolyt | KOH 100

Ersatz-Elektrolyt | KOH 100

15,20 EUR

pH-Elektrode (inkl. Pt1000-Sensor) | GE 117 BNC

pH-Elektrode (inkl. Pt1000-Sensor) | GE 117 BNC

226,00 EUR

Pepsin-Reinigungslösung | GRL 100

Pepsin-Reinigungslösung | GRL 100

9,15 EUR

Leitfähigkeitsmesszelle für universellen Einsatz | LF 400

Leitfähigkeitsmesszelle für universellen Einsatz | LF 400

376,00 EUR

robuste und präzise Leitfähigkeitsmesszelle | LF 425

robuste und präzise Leitfähigkeitsmesszelle | LF 425

387,00 EUR

Pufferlösung | PHL 4

Pufferlösung | PHL 4

21,40 EUR

Pufferlösung | PHL 7

Pufferlösung | PHL 7

21,40 EUR

Pufferlösung | PHL 10

Pufferlösung | PHL 10

21,40 EUR

tauchbare pH-Elektrode (inkl. Pt1000-Sensor) | GE 135 BNC

tauchbare pH-Elektrode (inkl. Pt1000-Sensor) | GE 135 BNC

179,00 EUR

Ersatzelektrode | GWO 5610

Ersatzelektrode | GWO 5610

268,00 EUR

Ersatzmembrankopf | GWOK 02

Ersatzmembrankopf | GWOK 02

32,30 EUR

Koffer | GKK 5001

Koffer | GKK 5001

55,30 EUR

Koffer | GKK 2021

Koffer | GKK 2021

127,10 EUR

Warenkorb

Sie haben noch keine Artikel in Ihrem Warenkorb.

Warenkorb »

Herzlich willkommen

E-Mail-Adresse:
Passwort:
Passwort vergessen?