general information:

HD3114B is a pressure, temperature and humidity handheld data logger with a large (43 x 58 mm) color graphic LCD display.

The instrument has a built-in precision barometric sensor for the measurement of the atmospheric pressure and the calculation of the following barometric and altimetric derived parameters: barometric tendency (numerical) and trend (decrease, steady, increase), altitude, QNH (atmospheric pressure at mean sea level calculated considering the international standard atmosphere - ISA), QFE (atmospheric pressure at ground level) and QFF (atmospheric pressure at mean sea level calculated considering the real temperature). The instrument can display the internal temperature of the barometric sensor.

The input for SICRAM probes (intelligent and interchangeable probes capable to store calibration data into memory) allows connecting:

  • 4-wire Pt100 temperature probes
  • temperature and relative humidity combined probes
  • TP704/TP705 absolute/relative/differential probes with PP471 module

The type of SICRAM probe connected is automatically recognized by the instrument. The probes are supplied factory-calibrated and are interchangeable. Calibration reports or certificates are available upon request.

By connecting a combined temperature and relative humidity probe, the instrument calculates the quantities derived from humidity: dew point temperature, wet bulb temperature, absolute humidity, mixing ratio, partial vapor pressure, saturated vapor pressure, enthalpy. Moreover, the DI discomfort index and the NET (Net Effective Temperature) index are calculated.

  • built-in precision barometric sensor
  • calculation of altimetric parameters QNH, QFE and QFF used in aeronautics and meteorology
  • one input for temperature, relative humidity and pressure SICRAM probes
  • automatic recognition of the probes
  • colour graphic display
  • graph display of a measurement
  • configurable measuring unit
  • data logging function with programming of auto start and auto stop
  • data storing on SD card for long logging duration
  • automatic creation of pdf reports
  • HOLD and REL (relative measurement) functions
  • detection of minimum, average and maximum values
  • password protected configuration
  • USB connection to PC
  • serial output for printer
  • rechargeable Battery
  • auto power off (configurable and excludable)


specifications:

atmospheric pressure
sensor:
precision piezo-resistive
measuring range: 0 to1,350 hPa
rsolution: 0.01 hPa
accuracy at 23°C:±0.1 hPa (500 to 1,200 hPa) / ±0.2 hPa (remaining range)
accuracy at full temperature range:±0.3 hPa (500 to 1,200 hPa) / ±0.4 hPa (remaining range)
long-term stability:0.25 hPa/year
available units of
measurement:
Pa, hPa, kPa, mbar, bar, atm, mmHg, mmH2O, kgf/cm2, PSI, inHg, inH2O  

 
instrument 
power supply:• Rechargeable internal 3.7 V lithium battery, capacity 2,250 mA/h, JST 3-pole connector.
• Optional external 5 V DC/1A power supply (SWD05) to be connected at the mini-USB connector of the instrument.
• Powered by the PC USB port (at least 500 mA) when connected to the PC.  
battery autonomy:15 hours of continuous operation (typical duration starting from a fully charged battery and with one Pt100 probe connected). The actual battery life depends on the type of the probe connected..  
logging interval:1, 5, 10, 15, 30 seconds / 1, 2, 5, 10, 15, 20, 30 minutes / 1 hour
storage capacity:SD memory card with capacity up to 4 GB.

The logging duration depends on the number of logged quantities and on the capacity of the SD card employed. For example: with a 4 GB SD card the duration of the logging is in the order of months, even when many quantities are recorded with the minimum logging interval equal to 1 s. 
inputs:1 input with 8-pole DIN45326 connector for Pt100 temperature probes, combined temperature and relative humidity probes, TP704/TP705 pressure probes with PP471 module.
The barometric sensor is integrated into the instrument.  
clock stability:1 min/month maximum drift  
display:color graphic LCD, visible area 43 x 58 mm  
USB Connection:1 USB port with mini-USB connector.  
RS232C connection:1 serial RS232C output with RJ12 (6P6C) connector for connecting to a serial printer. Baud Rate selectable from 1,200 to 115,200.  
auto power off:Configurable after 2, 5, 10, 15, 20 or 30 minutes from last pressure of a key, with battery supply. It can be disabled. Automatically disabled when powered from external supply.  
pperating conditions:-10 to +60°C, 0 to 85 % r.h. without condensation  
storage temperature:-25 to +65°C  
materials:ABS, protective 55 shore rubber bands on the sides. 55 shore rubber protective shell.  
dimensions:172 x 88 x 35 mm without rubber protection shell
180 x 102 x 46 mm with rubber protection shell  
weight:approx. 400 g (incl. batteries and protection shell)  
ingress protection:IP 64  




For further details p.r.t. data sheet:


 

 

 

Empfohlenes Zubehör | Weitere Artikel

tragbarer Thermodrucker | HD-40-1

tragbarer Thermodrucker | HD-40-1

360,00 EUR

Thermopapier | RCT

Thermopapier | RCT

27,10 EUR

33 % r.F. gesättigte Lösung | HD33

33 % r.F. gesättigte Lösung | HD33

111,90 EUR

Ersatzbatteriepack | BAT-40

Ersatzbatteriepack | BAT-40

49,50 EUR

wiederaufladbare 3,7 V Lithium-Ionen-Batterie | HD35-BAT1

wiederaufladbare 3,7 V Lithium-Ionen-Batterie | HD35-BAT1

49,50 EUR

Netzgerät | SWD-05

Netzgerät | SWD-05

60,10 EUR

75,4 % r.F. gesättigte Lösung | HD75

75,4 % r.F. gesättigte Lösung | HD75

111,90 EUR

Warenkorb

Sie haben noch keine Artikel in Ihrem Warenkorb.

Warenkorb »

Herzlich willkommen

E-Mail-Adresse:
Passwort:
Passwort vergessen?