Deutsch  English 


flow meter / monitor | FLEX with HD1K-...K

flow meter / monitor | FLEX with HD1K-...K


1.067,00 EUR

 inkl. 19 % USt  -> Preis zzgl. Versandkosten

Lieferzeit bzw. Fertigungszeit variiert - bitte erfragen!

Art.Nr.: FLEX-HD1K...K
construction type:
1K: standard:
analog output:
I: current output 4 mA to 20 mA:
U: voltage output 0 V to 10 V:
K: without any analog output:
nominal width of process connection:
008: DN 8:
010: DN 10:
015: DN 15 (+ 6,90 EUR) :
020: DN 20 (+ 129,50 EUR) :
025: DN 25 (+ 323,00 EUR) :
connection type:
G: internal thread:
connection material:
K: stainless steel:
switching value:
001: 0.1 to 1 l/min H2O:
005: 0.5 to 5 l/min H2O:
010: 1 to 10 l/min H2O:
020: 2 to 20 l/min H2O:
030: 3 to 30 l/min H2O:
040: 4 to 40 l/min H2O:
060: 6 to 60 l/min H2O:
080: 20 to 80 l/min H2O:
switching function:
L: minimum switch:
H: maximum switch:
R: frequency output:
K: without any switching output:
switching signal:
O: standard:
I: inverted:
switching output:
T: push pull (PNP and NPN):
K: without any switching output:
options for LABO / FLEX:
special range for analog output (standard = metering range) [l/min]:
special range for frequency output (standard = metering range) [l/min]:
end frequency (max. 2000 Hz) [Hz]:
power-on delay (from alarm to normal) [s]:
power-off delay (from O.K. to alarm) [s]:
power-on-delay (after connecting the supply, time during which the outputs are not actuated) [s]:
switching output fixed [l/min]:
special hysteresis (standard = 2 % EW) [%]:

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Produktbeschreibung


FLEX: evaluation electronic with analog output and switching function

general information:


The sensors work with a 16-bit processor, a 12-bit A/D and a 12-bit D/A converter. Linearisations and calibrations are carried out automatically. The Flash memory guarantees the exchangeability of all programs.

There is a choice between a switch with transistor output (push-pull) or a frequency output. The analog output 4 mA to 20 mA or 0 V to 10 V can be used at the same time. Many options are available for the switching outputs:


  • variable ranges for the analog outputs
  • variable hysteresis
  • minimum or maximum switches
  • inversion of the outputs
  • window function
  • delay after switching voltage on
  • switching delays (On, Off)

specifications:

appliance: flow, control
medium: water, oils (gases and aggressive media on request)
total measuring range: 0.1 l/min to 80 l/min H2O
connection: G 1/4 to G 1 internal thread, stainless steel
basic data: PN 200 bar,
temperature of medium -20°C to +85°C,
optionally -20°C bis +150°C


 

For further details p.r.t. data sheet:





instruction manual as .pdf:


 

 

 

Empfohlenes Zubehör | Weitere Artikel

Durchflusswächter | HD1K-...M/K

Durchflusswächter | HD1K-...M/K

0,00 EUR

Rundsteckverbinder 4-/5-polig | K...PU...

Rundsteckverbinder 4-/5-polig | K...PU...

0,00 EUR

Gerätekonfigurator | ECI-3

Gerätekonfigurator | ECI-3

697,00 EUR

Durchflussmesser / -wächter | FLEX mit HD1K-...M

Durchflussmesser / -wächter | FLEX mit HD1K-...M

660,00 EUR

Warenkorb

Sie haben noch keine Artikel in Ihrem Warenkorb.

Warenkorb »

Herzlich willkommen

E-Mail-Adresse:
Passwort:
Passwort vergessen?