air oxygen measuring transducer | OXY 3690MP
610,00 EUR
inkl. 19 % USt -> Preis zzgl. Versandkosten
Lieferzeit bzw. Fertigungszeit variiert - bitte erfragen!
Art.Nr.: OXY3690MPProduktbeschreibung
air oxygen measuring transducer incl. sensor
specifications:
| measuring ranges: | oxygen concentration: 0.0 % to 100.0 % O2 (gaseous) OXY 3690 MP: recommended range 0.2...35.0 vol. % O2 (reduced precision outside of this range) OXY 3690 MP-LO: also suitable for values ≤0.2 vol. % O2 temperature: -20.0°C to 50.0°C |
| accuracy (at nominal temperature 25°C): | oxygen: ±0.1 % ±1 digit temperature: ±0.1°C ±1 digit |
| output signal (only O2): | 4 to 20 mA (2-wire - standard), 0 to 10 V (3-wire - option) |
| electric isolation: | input electrically isolated |
| auxiliary energy: |
12 to 30 V DC (at output 4 to 20 mA) 18 to 30 V DC (at output 0 to 10 V - option) |
| perm. impedance (at 4 to 20 mA): |
RA [Ω] ≤ (Uv [V] - 12 V) / 0.02 A |
| permissible load (at 0 to 10 Volt): | RL >3,000 Ω |
| working conditions: | 0°C to +50°C, 0 % to +95 % r.h. (non-condensing) |
| storage temperature: |
-20°C to +70°C |
| reverse voltage protection: | 50 V permanently |
| display: | approx. 10 mm high, 4-digit LCD-display |
| housing: | ABS (IP65 - with the exception of sensor plug) |
| dimensions: | 82 x 80 x 55 mm (without elbow-type plug and sensor plug) |
| electric connection: | elbow-type plug acc. to EN 175301-803/A (IP65), max. wire cross section: 1,5 mm2, wire diameter from 4.5 to 7 mm |
| sensor connection: | 5-pin jack connector, screwable |
| calibration: | 1-point calibration in atmospheric air |
| air pressure compensation: | 500 to 2,000 hPa abs., manual input |
| oxygen sensor | |
| type: | depending on the version |
| measuring range: | 0.0 % to 100.0 % O2 |
| response time T90: | <10 s, depending on temperature |
| warranty: | 12 months (assuming appropriate usage according to the manual) |
| application area: | suitable for air and pure oxygen, protective gases |
| temperature compensation: | integrated in sensor housing |
| connection cable: | approx. 1.3 m, with 5-pin plug, screwable |
| operating pressure: | 500 to 2,000 hPa (static) for air and gas-stream use the option GOO.../MU |
| working conditions: | 0°C to +45°C, 0 % to +95 % r.h. (non-condensing) |
| storage temperature: | -15°C to +60°C |
| dimensions of housing: | approx. Ø 40 x 103 mm (153 mm incl. anti-buckling glanding), housing with M16 x 1-screw thread (sensor can be connected to line tubes by means of an included adapter piece) |
| weight: | approx. 135 g |
catalogue page as .pdf:
instruction manual as .pdf:
![]() |
Empfohlenes Zubehör | Weitere Artikel
Ersatzelektrode | GWO 3600267,00 EUR |
|
Luftsauerstoff-Sensor | GGO 370/GOO 370/GGA 370224,00 EUR |
|
Ersatz-Sensorelement | GOEL 370128,40 EUR |
|
Luftsauerstoff-Sensor | GGO 381/GOO 381/GGA 381273,00 EUR |
|
Ersatz-Sensorelement | GOEL 381181,00 EUR |