Deutsch  English 


signal converter / amplifier | HD978TR...

signal converter / amplifier | HD978TR...

Configurable signal converters/amplifiers with current or voltage output.

general information:


HD978TR3, HD978TR4, HD978TR5 and HD978TR6 are signal converters/amplifiers configurable with mV input. The mV input signal range can be configured from -10mV to +60mV via a button, by using the HD778-TCAL simulator and DeltaLog7 software or a tension calibrator with mV output. HD978TR3 and HD978TR5 have a 4 to 20mA current output. HD978TR4 and HD978TR6 have 0 to 10 V DC voltage output. 0 to 1 V DC, 0 to 5 V DC and 1 to 5 V DC outputs are available upon request. A LED indicates the alarm situation and it helps the user during the programming. The instrument is also protected against polarity inversions.

Input and output are galvanically isolated: this is necessary to eliminate problems due to the mutual influence of the devices originated by disturbs caused by the different mass paths. The device is housed in a DIN container (width 35 mm) with standard connection to a 35 mm DIN rail for the models HD978TR3 and HD978TR4 or in a housing for wall mounting for the models HD978TR5 and HD978TR6. The 4 to 20 mA current output stage of HD978TR3 and HD978TR5 is a passive two-wire and it supplies power to the converter through the current loop.


construction types:

HD978TR3
Configurable signal converter/amplifier with 4 to 20 mA (20 to 4 mA) output, for DIN rail mounting. Input measuring range -10 to +60 mV. Default setting 0 to 20 mV. Minimum measuring range 2 mV.

HD978TR4
Configurable signal converter/amplifier with 0 to 10 V DC (10 to 0 V DC) output, for DIN rail mounting. Input measuring range -10 to +60 mV. Default setting 0 to 20 mV. Minimum measuring range 2 mV.

HD978TR5
Configurable signal converter/amplifier with 4 to 20 mA (20 to 4 mA) output, for wall mounting. Input measuring range -10 to +60 mV. Default setting 0 to 20 mV. Minimum measuring range 2 mV.

HD978TR6
Configurable signal converter/amplifier with 0 to 10 V DC (10 to 0 V DC) output, for wall mounting. Input measuring range -10 to +60 mV. Default setting 0 to 20 mV. Minimum measuring range 2 mV.


specifications:

input
measuring range: -10 mV to +60 mV configurable
default range: 0 mV to 20 mV
minimum measuring range:
2 mV
input impedance:
>1 MOhm
conversion speed:2 measures per second 
accuracy:
±0.04 %F.S. ±20 μV
operating temperature:-30°C to +70°C
storage temperature:-40°C to +80°C
relative humidity:0 % to 90 % r.h. (without condensation)


output
type of output:HD978TR3 und TR5: 4 to 20 mA (or 20 to 4 mA), two-wired, 22 mA, in case of unconnected input
HD978TR4 und TR6: 0 to 10 V DC, (0 to 1 V CC, 0 to 5 V DC, 1 to 5 V DC upon request)
resolution:HD978TR3 und TR5: 4 µA
HD978TR4 und TR6: 20 µA
protection against polarity inversion:40 Vmax
sensitivity to V DC power voltage
variations:
HD978TR3 und TR5: 0.4 µA/V
HD978TR4 und TR6: 2 µA/V
load resistance:
HD978TR3 und TR5:
RLMax = (V CC - 9) / 0.022
RLMax = 625 Ω mit V DC = 24 V DC
HD978TR4 und TR6: >10 kΩ
input/output
galvanic isolation:
50 V CC (verified at 250 V)
red LED:
it turns on while programming, when the probe is broken
or not connected
heating time:2 minutes
thermal drift:0.02 % F.S./°C




For further details p.r.t. data sheet:


 

 

 

Recommended products

pyranometer | LP PYRA 02...

pyranometer | LP PYRA 02...

0,00 EUR

pyranometer | LP PYRA 03...

pyranometer | LP PYRA 03...

0,00 EUR

pyranometer | LP PYRA 12...

pyranometer | LP PYRA 12...

0,00 EUR

Shopping Cart

You have no articles inside your cart

Shopping Cart »

Welcome back

E-mail-address:
password:
lost password?