model:
EX-protection:
lightning protection:
measuring range:
0B1: 0.1 bar:
0B25: 0.25 bar:
0B4: 0.4 bar:
0B6: 0.6 bar:
01B: 1 bar:
1B6: 1.6 bar:
2B5: 2.5 bar:
04B: 4 bar:
06B: 6 bar:
10B: 10 bar:
output:
A1: 4 to 20 mA:
V2: 0 V to 10 V:

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Produktbeschreibung


Price upon request!

measuring probe for tank contents - for diffi cult measuring conditions

general information:


Piezo-resistive pressure sensor with temperature compensation. Welded, non-corrosive
design with stationary casted and additionally sealed water-proof connection cable. The pressure compensation is done via a cable-integrated air path to the atmosphere. A special feature of GBS 02 is the lateral flow resistance, which prevents media ingress.

application:

For measuring the level of fuel oil, diesel and other aggressive media. The sensor is highly precise, insensitive to lateral flow and offers various special options like lightning protection and other output signals (e.g. 0 V to 10 V). For measuring of gasoline please order ex-design.

specifications:

measuring ranges:                      
0.1 bar ... 10 bar = 1 ... 100 m water column

    available ranges:0.1   0.25,   0.4,   0.6,   1,   1.6,   2.5,   4,   6,   10
    overload limit (bar):
  1        2        2       3      5      8       8    10  10   10
output signal:                        
4 mA to 20 mA (option: 0 V to 10 V)

permissible impedance: 4 mA to 20 mA: RA [Ω] < (Uv [V] -10 V) / 0.02 A

permissible load: 0 V to 10 V: RL [Ω] > 100 kOhm

auxiliary energy: 10 V DC to 30 V DC (14 V DC to 30 V DC at 0 V to 10 V)
accuracy:characteristic curve deviation (% of span):
≤ 0.25 limit point setting resp. ≤0.125 (BFSL); (at 0.1 bar: ≤0.5
limit point setting resp. ≤0.25 (BFSL))

hysteresis
(% of span):
≤0.1
repeatabilty
(% of span):
≤0.05
stability per year
(% of span):
≤0.2 (at reference conditions)
operating temperature: -10°C to +85°C
temperature coefficient
(% of span):
≤ 0.02 / K (for measuring range > 0.4 bar)
filling:KN77, food safe
housing:chromium-nickel alloy 1.4571. External thread G 1/2“ accessible
after removal of plastic protection cap.

probe dimensions:Ø 27 mm, length of metal body: approx. 147 mm,
cable approx. Ø 7.5 mm

connection:measuring range <1 bar: 10 m, measuring range >1 bar: 15 m stationary casted FEP cable, loose ends.
Glass-fibre screen protects cable against tearing. (Extra long cable for an additional charge - please specify when ordering).