Deutsch  English 


universal displaying and regulating device | GIR 2002

universal displaying and regulating device | GIR 2002


267,00 EUR

 inkl. 19 % USt  -> Preis zzgl. Versandkosten

Lieferzeit in der Regel ca. 1 Woche

Art.Nr.: GIR2002
model:
00: standard version:
supply voltage:
230A: 230 V AC:
012D: 12 V DC (+ 37,00 EUR) :
012DA: 12 V DC (analog output or NPN switching output or REL3 or HLR3) (+ 71,20 EUR) :
024D: 24 V DC (+ 37,00 EUR) :
024DA: 24V DC (continuous/analog output or NPN switching output) (+ 71,20 EUR) :
115A: 115 V AC (+ 21,20 EUR) :
output:
R1: relay, normally open:
H1: solid-state relay:
AA1: analog output 0(4) to 20 mA (+ 81,30 EUR) :
AV1: analog output 0 to 10 V (+ 81,30 EUR) :
output 2:
R2: relay, changeover:
H2: solid-state relay:
output 3:
00: no 3rd output:
R3: relay, changeover (+ 66,90 EUR) :
H3: solid-state relay (+ 66,90 EUR) :
AA3: analog output 0(4) to 20 mA (+ 128,50 EUR) :
AV3: analog output 0 to 10 V (+ 128,50 EUR) :

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Produktbeschreibung


universal displaying and regulating device with on/off- or PID-control mode

general information:

Due to its compact construction and easy handling, the universal controller GIR 2002 is the ideal device for simple control systems (on/off switching, relay outputs,...).

The basic version of GIR 2002 PID offers a control output for a 2-point-control with the control modes P, I, PI, PD or PID and a second control output for on/off switching. The device can also be configured as a 3-point step controller or as a controller with continuous output (optionally).

Due to the universal input and the various switching functions, the controller can be adapted optimally to the requirements of the system. The structured menu navigation allows a straightforward handling and a fast adjustment of the parameters. A LED switching state indicator gives information to the user about the current status of
the switching outputs. An extensive self-monitoring and diagnostic system ensures maximum operational safety and reports systems errors by conclusive error codes. The parameters are automatically saved, so that all data will be maintained even in case of a power blackout.

Most of the Greisinger transmitters, rotational speed sensors and flow rate sensors can be connected directly to the integrated transmitter power supply (24 V DC / 22 mA) of the controller.

If the device is used as a thermocouple or resistance thermometer, the measuring value
can be alternatively displayed in °C or °F. Additionally an offset value for the correction of measuring values can be entered (e.g. reconciliation of the resistivity of the wires). The current and voltage inputs are freely scalable in the range -1,999 to +9,999.

GIR 2002 has a serial, bus-compatible interface by default. Therefore a comfortable programming of the parameters as well as the recording of measuring values are possible. With the optionally available Windows library EASYBUS.dll up to 240 devices can be integrated into own programs (z.B. LabView).

applications:

  • process control
  • temperature controller
  • pressure monitoring
  • indication of rotational speed
  • flow counter, etc.


specifications:

measuring input
measuring / display range
accuracy
(at nominal temperature)
thermocouples
(4 measurements / s):                               


FeCu-Ni
(type J, IEC 584):
-70.0°C to +300.0°C or
-170°C to +950°C
<0.3 % FS ±1 digit *
NiCr-Ni
(type K, IEC 584):
-70.0°C to +250.0°C or
-270°C to +1,372°C
<0.3 % FS ±1 digit *
NiCrSi-NiSi
(type N, IEC 584):
-100.0°C to +300.0°C or
-270°C to +1,350°C
<0.3 % FS ±1 digit *
Pt10Rh-Pt
(type S, IEC 584):
-50°C to +1,750°C
<0.5 % FS ±1 digit *
Cu-CuNi
(type T, IEC 584):
-70.0°C to +200.0°C or
-270°C to +400°C
<0.3 % FS ±1 digit *

* = point of comparison: ±1 °C



resistance thermometer (4 measurements / s)


Pt 100
(3-wire, DIN EN
60751):                                 
-50.0°C to +200.0°C or
-200°C to +850°C
<0.3 % FS ±1 digit
Pt1000
(2-wire, DIN EN 60751)
:
-200°C to +850°C<0.3 % FS ±1 digit



process signals / standard signals (100 measurements / s)

0 V to 1 V, 0 V to 2 V,
0 V to 10 V:
-1,999 to +9,999 digit,
freely scalable
<0.2 % FS ±1 digit
0 mA to 20 mA, 4 mA to 20 mA: -1,999 to +9,999 digit,
freely scalable
<0.2 % FS ±1 digit
0 mV to 50 mV: -1,999 to +9,999 digit,
freely scalable
<0.3 % FS ±1 digit



frequency

TTL signal: 0.000 Hz to 10 kHz,
freely scalable
<0.1 % FS ±1 digit
switching contact NPN: 0.000 Hz bis 3 kHz,
freely scalable
<0.1 % FS ±1 digit
switching contact PNP:0.000 Hz bis 1 kHz,
freely scalable
<0.1 % FS ±1 digit
rotational speed:0.000 U/min to 9,999 U/minselectable prescaler: 1 to  1,000, pulse frequency: max. 600,000 Imp./min at TTL
flow:0 l/s to 9,999 l/s, 0 l/min to 9,999 l/min or 0 l/h to 9,999 l/h



counter up/down


TTL signal,
switching contact
(NPN, PNP):
0 to 9,999 or 0 to 999,000
(with prescaler), selectable prescaler: 1 to 1,000, pulse frequency: max. 10,000 Imp./s at TTL
<0.1 % FS ±1 digit






serial interface: displaying and controlling of values coming via the serial interface

switching functions: 5 or 6, selectable (e.g. 2-point regulator, 3-point regulator, ...)

switching point,
hysteresis:
freely selectable

response time:≤25 ms at standard signal; ≤0.5 s at  temperature and frequency
display:approx. 13 mm high, 4-digit red LED display

interface:serial interface, galv. isolated, EASYBus compatible
transmitter supply:24 V DC ±2 %, 22 mA at 230 V AC voltage supply
18 V DC ±2 %, 22 mA at 12 V DC or 24 V DC voltage supply

miscellaneous:permanent self-monitoring, digital filter function, measuring range boundary (limit)
power consumption:approx. 6 VA
operating conditions:-20°C to +50°C, 0 % to 80 % r.h. (non-condensing)
panel mounting:with fixing clamps
electrical connection:via screw-type/plug-in terminals
wire cross-section from 0.14
mm2 to 1.5 mm2

ingress protection:front side IP54, IP65 upon request

housing:standard rack type housing
dimensions:96 x 48 mm (W x H) (front frame)

mounting depth:approx. 115 mm (with fixing clamps)
panel cut-out:90.5+0.5 x 43.0+0.5 mm (W x H)

outputs: p.r.t. data sheet
Please note: Not all options are available for both device types and not all options
can be combined with each other. Please see therefore the matrix on the data sheet
.


 

catalogue page as .pdf:

 

 

 

Empfohlenes Zubehör | Weitere Artikel

Software für Messdatenerfassung | EBS 20M / 60M

Software für Messdatenerfassung | EBS 20M / 60M

121,00 EUR

Zusatzdichtung für Gehäuseeinbau IP65 | GGD 4896

Zusatzdichtung für Gehäuseeinbau IP65 | GGD 4896

5,70 EUR

Einheitenaufkleber | EAK 36

Einheitenaufkleber | EAK 36

1,55 EUR

Warenkorb

Sie haben noch keine Artikel in Ihrem Warenkorb.

Warenkorb »

Herzlich willkommen

E-Mail-Adresse:
Passwort:
Passwort vergessen?

Top Artikel