universal display and controlling device | GIA 20 EB
203,00 EUR
inkl. 19 % USt -> Preis zzgl. Versandkosten
Lieferzeit in der Regel ca. 1 Woche
Art.Nr.: GIA20EBProduktbeschreibung
alternative to DP 4824 and EASYBus sensor module EBN
general information:
- universal inputs for standard signals, frequency, Pt100, Pt1000 and thermocouples
- configurable as display or controller (5 switching functions)
- comprehensive self-monitoring and diagnostic system
- limit functions, digital filter, min/max value memory
- alarm delay adjustable
specifications:
measuring input: | universal input for standard signal: 4 mA to 20 mA, 0 mA to 20 mA, 0 V to 1 V, 0 V to 2 V, 0 V to 10 V, 0 mV to 50 mV resistance thermometer: Pt100 (3-wire), Pt1000 (2-wire) thermocouples: Typen J, K, N, S, T frequency, rotational speed: TTL signal, switching contact up- / down-counter: TTL signal, switching contact serial interface |
measuring rate: | approx. 100 measurements/s (standard signal) or approx. 4 measurements/s (temperature and frequency) |
measuring and display range, resolution | |
temperature (display unit switchable from °C to °F): |
Pt100: -200°C to +850°C or -50.0°C to +200.0°C; Pt1000: -200°C to +850°C; type J: -170°C to +950°C; type K: -270°C to +1,350°C; type N: -270°C to +1,300°C; type S: -50°C to +1,750°C; type T: -270°C to +400°C |
standard signals: | -1,999 to 9,999 digit, initial value, final value and DP freely selectable recommended range: ≤2,000 digit |
frequency: | 0.000 Hz to 10 kHz, display freely scalable |
rotational speed: | 0.000 U/min to 9,999 U/min, selectable prescaler: 1 to 1,000 |
up- / down-counter: | counter reading is stored also in power-down state 0 to 9,999 (10 mio. with prescaler), pulse frequency: ≤10 kHz, selectable prescaler: 1 to 1,000 |
serial interface: | display and control functions with values obtained via serial interface |
accuracy (at nominal temperature = +25°C) | |
standard signal: | <0.2 % FS ±1 digit (at 0 mV to 50 mV: <0.3 % FS ±1 digit) |
resistance thermometer: | <0.5 % FS ±1 digit |
thermocouple: | <0.3 % FS ±1 digit (for type S: <0.5 % FS ±1 digit) |
point of comparison accuracy: | ±1°C |
frequency, rotational sped, counter: | <0.1 % FS ±1 digit |
outputs: | 2 switching outputs, not electrically isolated |
switching function: | 2-point, 3-point, 2-point with alarm, min/max alarm with 1 output, min/max alarm with 2 outputs |
switching points, switching hysteresis: | freely selectable |
response time: | ≤20 ms for standard signal ≤0.5 s for temperature and frequency |
display: | approx. 10 mm high, 4-digit red LED display |
operation: | with 3 push-buttons (accessible after removing the frontpanel) |
option: | FS3T, frontpanel with 3 push-buttons for comfortable configuration. Problem-free replacement is possible. |
interface: | serial interface, galvanicallly isolated, EASYBus compatible |
miscellaneous: | continuous self-diagnostics, digital filter function, measuring range limitation |
voltage supply: | 9 V DC to 28 V DC (standard) optionally: electrically isolated voltage supply 11 V to 13 V (G12) or 22 V to 27 V (G24) |
power consumption: | max. 30 mA (without switching outputs) |
nominal temperature: | +25°C |
working temperature: | -20°C to +50°C |
relative humidity: | 0 % to 80 % r.h. (non-condensing) |
storage temperature: | -30°C to +70°C |
panel mounting: | with VA-spring clamp possible panel thicknesses: from 1 mm to approx. 10 mm |
electrical connection: | via screw-type/plug-in terminals: 2-pole for interface and 9-pole for other connections, cable cross section from 0.14 mm2 to 1.5 mm2 |
ingress protection: | front side IP54 |
housing: | glass fibre reinforced Noryl,front panel polycarbonate |
dimensions: | 48 x 24 mm (W x H) (front frame) mounting depth: approx. 65 mm (incl. screw-type/plug-in terminal) panel cut-out: 45+0.5 x 21.7+0.5 mm (W x H) |
special version GIA 20 EB/PK:
Universal display and controlling device with individually programmable linearisation characteristic line
The adjustment to the measured quantity is done with the configuration software (free of charge) via the integrated interface. For the connection to the PC, an interface converter EBW 1 or EBW 3 is required. Input values (in mA, V, Ohm, Hz) and corresponding display values can be entered in the configuration software.
catalogue page as .pdf: |
instruction manual GIA 20 EB as .pdf: |
instruction manual GIA 20 EB electrically isolated as .pdf: |