transducer for temperature and humidity | HD 9008TRR
368,00 EUR
inkl. 19 % USt -> Preis zzgl. Versandkosten
Lieferzeit bzw. Fertigungszeit variiert - bitte erfragen!
Art.Nr.: HD9008TRRProduktbeschreibung
dual, passive, meteorological microprocessor transducer for humidity and temperature,
4 mA to 20 mA output
general information:
HD9008TRR is a single block microprocessor transducer for humidity and temperature, temperature is configurable. The HD9008TRR is a passive transmitter with a 4 mA to 20mA output and 10 V DC to 40 V DC power supply. The sensors are mounted at the end of a plastic tube: a capacitive humidity sensor and a platinum temperature sensor (100 Ω @0°C).
The instrument can be reprogrammed by means of a key, and no jumper or potentiometer actions are required. The humidity input can be recalibrated by using two saturated solutions: the first one at 75 %, the second one at 33 %; the elative humidity range 0 % to 100 % r.F. r is fixed, 4 mA correspond to 0 % r.F., 20 mA equal 100 % r.F.
The temperature standard configuration is –40°C to +80°C, corresponding to 4 mA to 20 mA. The user can configure the temperature output in ranges different from the standard one by means of a Pt100 simulator or of a set of fixed resistances, provided that it is included within the -40°C to +80°C range and shows a minimum amplitude of 25°C. Two LEDs give alarm indications (temperature exceeding set range, sensor breakage or shortcircuit) and help the operator when programming.
An out-of-standard temperature operating range can be requested when placing the order.
Important warning: the probes work in the -40°C to +80°C temperature range. Outside of this range data are not correct; electronics are designed to operate within this range.
specifications:
operating temperature: |
electronics and sensor: -40°C to +80°C |
power supply transducer: |
10 V DC to 40 V DC (4 mA to 20 mA) |
humidity: | |
capacity: | 300 pF typ. |
measuring range: | 0 % to 100 % r.h. |
accuracy at +20°C: | ±1.5 % r.h. (0 % to 90 % r.h.) ±2.0 % r.h. (for the remaining values of the scale) |
response time at 63 % of final variation: | 3 min with filter; 6 s without filter no thermal shock |
output signal: | 0 % r.h. = 4.0 mA 100 % r.h. = 20.0 mA |
load resistance: | RLmax = (VCC-10)/22 mA |
temperature: | |
measuring range - standard configuration: |
-40°C to +80°C |
accuracy: |
±0.15°C ±0.1% of measurement |
response time at 63 % of final variation: |
3 min; 6 s without filter |
output signal: |
-40°C = 4.0 mA +80°C = 20.0 mA |
load resistance: |
RLmax = (VCC-10)/22 mA |
dimensions: | Ø 26 x 225 mm |
max. cable length: | 200 m |
min. wire section: | 20 AWG – 0.5 mm² |
max. cable diameter: | Ø 5 mm |
For further details p.r.t. data sheet:
Empfohlenes Zubehör | Weitere Artikel
33 % r.F. gesättigte Lösung | HD33111,90 EUR |
|
Temperatur- und Feuchtemessumformer | HD 9009TRR368,00 EUR |
|
Lamellen-Strahlungsschirm | HD 9007178,00 EUR |