transducer for conductivity | GLMU 400 MP
694,00 EUR
inkl. 19 % USt -> Preis zzgl. Versandkosten
Lieferzeit in der Regel ca. 1 Woche
Art.Nr.: GLMU400MPProduktbeschreibung
conductivity measuring transducer. 4-pole measuring cells incl.
general information:
Cost-efficient conductivity measurement in drinking water, lake water, process water and waste water, operational.
- compact measuring cells
- freely scalable
- adjustable cell constant
- local display
- integrated temperature compensation
- 4-pole measuring cell included, pre-adjusted
application areas:
especially well-suited for use above 2,000 μS/cm, for susceptible applications, sea water, etc.
specifications:
measuring ranges: (costumer selectable)
conductivity: | 0.0 μS / cm to 200.0 μS / cm 0 μS / cm to 2,000 μS / cm 0.00 mS / cm to 20.00 mS / cm 0.0 mS / cm to 200.0 mS / cm 0 mS / cm to 500 mS / cm |
||
specific resistance: | 0.0 kOhm*cm to 200.0 kOhm*cm 0.00 kOhm*cm to 20.00 kOhm*cm 1 Ohm*cm to 5,000 Ohm*cm 1.0 Ohm*cm to 500.0 Ohm*cm 1.00 Ohm*cm to 50.00 Ohm*cm |
||
TDS: | 0.0 mg / l to 200.0 mg / l 0 mg / l to 500.0 mg / l 0 mg / l to 2,000 mg / l 0.0 g / l to 20.0 g / l 0 g / l to 200 g / l |
||
salinity: | 0.0 to 70.0 (PSU) |
||
temperature measurement: | -5.0°C
to +140.0°C (device), please note permissible temperature of the measuring cell |
||
measuring cell: |
|
||
accuracy: (at nominal temperature = 25°C) |
conductivity: +0.5 % of measured value +0.3 % FS (-RW: +1 % of measured value +0.3 % FS) | ||
temperature: +0.2°C +1 digit | |||
connection of measuring cells: |
7-pole diode socket |
||
cell constant: |
K = 0.30 to 1.20, adjustable (-RW: 0.03 to 0.12) |
||
temperature compensation: (customer selectable) |
off: no compensation Lin: linear compensation (0.3 to 3.0 %/K) nLF: non-linear compensation for natural water according to EN27888 (ISO 7888) at salinity: automatic according to IOT |
||
display: | approx. 10 mm high, 4-digit LCD-display | ||
output signal: |
4 mA to 20 mA (2-wire), standard 0 V to 1 V or 0 V to 10 V (3-wire), surcharge |
||
galvanic isolation: | input galvanically isolated | ||
auxiliary power: |
12 V DC to 30 V DC (for option 0 V to 10 V: 18 V DC to 30 V DC) |
||
polarity protection: | 50 V continuous | ||
perm. burden: | (at 4 mA to 20 mA): RA[Ω] ≤ (Uv [V] - 12 V) / 0.02 A | ||
per. load: | (at 0 V to 10 V): RL > 3,000 Ω | ||
working temperature: |
-25°C to +50°C
(transducer) 0°C to +80°C (measuring cell) |
||
storage temperature: | -25°C to +70 °C | ||
electrical connection: |
angle connector according to EN 175301-803/A (IP 65) |
||
housing: | ABS (IP65) except electrode connection sockets | ||
dimensions: | 82 x 80 x 55 mm, without angle plug and socket | ||
warranty: | 12 months | ||
mounting: | with fixing holes for wall mounting, ounting distance: 70 x 50 mm (W x H) |
catalogue page as .pdf: |
instruction manual as .pdf: |
Empfohlenes Zubehör | Weitere Artikel
Leitfähigkeitskontrolllösung | GKL 1009,15 EUR |
|
Leitfähigkeitskontrolllösung | GKL 10157,80 EUR |
|
Leitfähigkeitskontrolllösung | GKL 1029,15 EUR |
|
Aufsteck-Gewindeadapter | PG 13.56,90 EUR |
|
Gewindeadapter | GWA1Z23,30 EUR |
|
Ersatzmesszelle, 4-polig | LFE 400342,00 EUR |
|
Ersatzmesszelle, 4-polig | LFE 430326,00 EUR |
|
Verbindungskabel | VKMU-M1284,80 EUR |