Deutsch  English 


transducer for conductivity | GLMU 400 MP-UNI

transducer for conductivity | GLMU 400 MP-UNI


413,00 EUR

 inkl. 19 % USt  -> Preis zzgl. Versandkosten

Lieferzeit in der Regel ca. 1 Woche

Art.Nr.: GLMU400MP-UNI
measuring cells/electrodes:
without measuring cell:
SW: 4-pole measuring cell LFE 400 for susceptible applications, without thread, not pressure resistant (only with option PG up to 6 bar), Ø 12 mm, made of graphite, C = 0.55; -5°C to +80°C, standard cable length 1 m (+ 342,00 EUR) :
TR: 2-pole measuring cell LFE-202 for potable/fresh water, without thread, not pressure resistant (only with option PG up to 6 bar), Ø 12 mm, made of graphite, C = 1.0; -5°C to +80°C, standard cable length 1 m (+ 166,50 EUR) :
TR-PG: 2-pole measuring cell LFE-202-PG for potable/fresh water, with fixed PG 13.5 thread, 6 bar max., Ø 12 mm, made of graphite, C = 1.0; -5°C to +80°C, standard cable length 1 m (+ 226,00 EUR) :
SWP: 4-pole screw-in measuring cell LFE 430 for susceptible applications, field mounting M12, G 1/2 A, 16 bar max., Ø 16 mm, made of graphite, C = 0.4; 0°C to +60°C (higher upon request), standard cable length 5 m (+ 326,00 EUR) :
TRP: 2-pole screw-in measuring cell LFE-230 for potable/fresh water, field mounting M12, G 1/2A, 16 bar max., Ø 16 mm, made of graphite, C = 0.9; 0°C to +60°C (higher upon request), standard canle length 5 m (+ 233,00 EUR) :
LTG: 2-pole measuring cell LFE-210 for organic substances, not pressure resistant, Ø 12 mm, made of glass/platinum, C= 1.0; standard cable length 1 m (+ 461,00 EUR) :
SW-PG: 4-pole measuring cell LFE 400-PG for susceptible applications, with fixed PG 13.5 thread, 6 bar max., Ø 12 mm, made of graphite, C = 0.55; -5°C to +80°C, standard cable length 1 m (+ 401,00 EUR) :
RW: 2-pole measuring cell LFE-240 for ultrapure water, not pressure resistant, Ø 12 mm, made of stainless steel/PEEK, C = 0.1; -5°C to +80°C, standard cable length 1 m (+ 199,00 EUR) :
RWP: 2-pole screw-in measuring cell LFE-220 for ultrapure water, field mounting M12, G 1/2 A, 16 bar max., Ø 12 mm, made of stainless steel/PEEK, C = 0.1; -10°C to +100°C (higher upon request), standard cable length 5 m (+ 249,00 EUR) :
output:
A1: 4 to 20 mA:
AV01: output signal 0 to 1 V (+ 33,30 EUR) :
AV010: 0 to 10 V (+ 33,30 EUR) :
options GR :
LACK: blank lacquered on both sides (for outdoor applications) (+ 17,90 EUR) :

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Produktbeschreibung


conductivity measuring transducer without measuring cell, suitable for 2- and 4-pole measuring cells

general information:

Cost-efficient conductivity measurement in drinking water, lake water, process water and waste water.

  • freely scalable
  • adjustable cell constant
  • local display
  • integrated temperature compensation
  • measuring cell not included


for composing your own conductivity measuring system with special measuring cells


specifications:


measuring ranges: (costumer selectable)

conductivity: 0.0 μS / cm to 200.0 μS / cm
0
μS / cm to 2,000 μS / cm
0.00
mS / cm to 20.00 mS / cm
0.0
mS / cm to 200.0 mS / cm
0
mS / cm to 500 mS / cm

specific resistance: 0.0 kOhm*cm to 200.0 kOhm*cm
0.00
kOhm*cm to 20.00 kOhm*cm
1
Ohm*cm to 5,000 Ohm*cm
1.0
Ohm*cm to 500.0 Ohm*cm
1.00
Ohm*cm to 50.00 Ohm*cm
TDS: 0.0 mg / l to 200.0 mg / l
0
mg / l to 500.0 mg / l
0
mg / l to 2,000 mg / l
0.0
g / l to 20.0 g / l
0
g / l to 200 g / l
salinity: 0.0 to 70.0 (PSU)
temperature measurement: -5.0°C to +140.0°C (device), please note permissible temperature of the measuring cell


accuracy:
(at nominal temperature = 25°C)
conductivity: +0.5 % of measured value +0.3 % FS (-RW: +1 % of measured value +0.3 % FS)
temperature: +0.2°C +1 digit
connection of measuring cells: 7-pole diode socket
cell constant: K = 0.30 to 1.20, adjustable (-RW: 0.03 to 0.12)
temperature compensation:
(customer selectable)
off: no compensation
Lin: linear compensation (0.3 to 3.0 %/K)
nLF: non-linear compensation for natural
         water according to EN27888 (ISO
         7888)
at salinity: automatic according to IOT

display: approx. 10 mm high, 4-digit LCD-display
output signal: 4 mA to 20 mA (2-wire), standard
0 V to 1 V or 0 V to 10 V (3-wire), surcharge
galvanic isolation: input galvanically isolated
auxiliary power: 12 V DC to 30 V DC
(for option 0 V to 10 V: 18 V DC to 30 V DC)
polarity protection: 50 V continuous
perm. burden: (at 4 mA to 20 mA): RA[Ω] (Uv [V] - 12 V) / 0.02 A
per. load: (at 0 V to 10 V):  RL > 3,000 Ω
working temperature: -25°C to +50°C (transducer)
storage temperature: -25°C to +70 °C
electrical connection: angle connector according to EN 175301-803/A (IP 65)
housing:ABS (IP65)  except electrode connection sockets
dimensions:82 x 80 x 55 mm, without angle plug and socket
warranty:12 months
mounting:with fixing holes for wall mounting, ounting distance: 70 x 50 mm (W x H)

 

catalogue page as .pdf:
instruction manual as .pdf:

 

 

 

Empfohlenes Zubehör | Weitere Artikel

Leitfähigkeitskontrolllösung | GKL 100

Leitfähigkeitskontrolllösung | GKL 100

9,15 EUR

Leitfähigkeitskontrolllösung | GKL 101

Leitfähigkeitskontrolllösung | GKL 101

57,80 EUR

Leitfähigkeitskontrolllösung | GKL 102

Leitfähigkeitskontrolllösung | GKL 102

9,15 EUR

Aufsteck-Gewindeadapter | PG 13.5

Aufsteck-Gewindeadapter | PG 13.5

6,90 EUR

Gewindeadapter | GWA1Z

Gewindeadapter | GWA1Z

23,30 EUR

Ersatzmesszelle, 2-polig | LFE 202

Ersatzmesszelle, 2-polig | LFE 202

166,50 EUR

Ersatzmesszelle, 2-polig | LFE 210

Ersatzmesszelle, 2-polig | LFE 210

461,00 EUR

Ersatzmesszelle, 2-polig | LFE 220

Ersatzmesszelle, 2-polig | LFE 220

249,00 EUR

Ersatzmesszelle, 2-polig | LFE 230

Ersatzmesszelle, 2-polig | LFE 230

233,00 EUR

Ersatzmesszelle, 2-polig | LFE 240

Ersatzmesszelle, 2-polig | LFE 240

199,00 EUR

Ersatzmesszelle, 4-polig | LFE 400

Ersatzmesszelle, 4-polig | LFE 400

342,00 EUR

Ersatzmesszelle, 4-polig | LFE 430

Ersatzmesszelle, 4-polig | LFE 430

326,00 EUR

Verbindungskabel | VKMU-M12

Verbindungskabel | VKMU-M12

84,80 EUR

Warenkorb

Sie haben noch keine Artikel in Ihrem Warenkorb.

Warenkorb »

Herzlich willkommen

E-Mail-Adresse:
Passwort:
Passwort vergessen?

Top Artikel