Deutsch  English 


transducer for conductivity | GLMU 200 MP

transducer for conductivity | GLMU 200 MP


539,00 EUR

 inkl. 19 % USt  -> Preis zzgl. Versandkosten

Lieferzeit in der Regel ca. 1 Woche

Art.Nr.: GLMU200MP
measuring cells/electrodes:
TR: 2-pole measuring cell LFE-202 for potable/fresh water, without thread, not pressure resistant (only with option PG up to 6 bar), Ø 12 mm, made of graphite, C = 1.0; -5°C to +80°C, standard cable length 1 m:
TR-PG: 2-pole measuring cell LFE-202-PG for potable/fresh water, with fixed PG 13.5 thread, 6 bar max., Ø 12 mm, made of graphite, C = 1.0; -5°C to +80°C, standard cable length 1 m (+ 32,00 EUR) :
TRP: 2-pole screw-in measuring cell LFE-230 for potable/fresh water, field mounting M12, G 1/2A, 16 bar max., Ø 16 mm, made of graphite, C = 0.9; 0°C to +60°C (higher upon request), standard canle length 5 m (+ 148,00 EUR) :
LTG: 2-pole measuring cell LFE-210 for organic substances, not pressure resistant, Ø 12 mm, made of glass/platinum, C= 1.0; standard cable length 1 m (+ 295,00 EUR) :
RW: 2-pole measuring cell LFE-240 for ultrapure water, not pressure resistant, Ø 12 mm, made of stainless steel/PEEK, C = 0.1; -5°C to +80°C, standard cable length 1 m (+ 33,00 EUR) :
RWP: 2-pole screw-in measuring cell LFE-220 for ultrapure water, field mounting M12, G 1/2 A, 16 bar max., Ø 12 mm, made of stainless steel/PEEK, C = 0.1; -10°C to +100°C (higher upon request), standard cable length 5 m (+ 164,00 EUR) :
output:
A1: 4 to 20 mA:
AV01: output signal 0 to 1 V (+ 33,30 EUR) :
AV010: 0 to 10 V (+ 33,30 EUR) :
options GR :
LACK: encapsulated PC board (+ 17,90 EUR) :
optional cable lengths:
Optional cable length for the construction types with 1 m cable as standard.
L02: 2 m (+ 5,45 EUR) :
L03: 3 m (+ 10,80 EUR) :
L04: 4 m (+ 16,40 EUR) :
L05: 5 m (+ 21,80 EUR) :

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Produktbeschreibung


conductivity measuring transducer. 2-pole measuring cells incl.

general information:

Cost-efficient conductivity measurement in drinking water, lake water, process water and waste water, operational.

  • compact measuring cells
  • freely scalable
  • adjustable cell constant
  • local display
  • integrated temperature compensation
  • 2-pole measuring cell included, pre-adjusted


GLMU 200 MP-TR: conductivity measuring transducer, incl. 2-pole measuring cell for use in pure / potable / fresh water

GLMU 200 MP-LTG: conductivity measuring transducer, incl. 2-pole measuring cell for use in organic substances (alcohol, petrol, diesel)

GLMU 200 MP-RW: conductivity measuring transducer, incl. 2-pole measuring cell for use in pure/ultra pure water measuring systems


specifications:


measuring ranges: (costumer selectable)


GLMU 200 MP                           GLMU 200 MP-RW
conductivity: 0.0 to 200.0 µS/cm,                  0.0 to 200.0 µS/cm,
0 to 2,000 µS/cm,                      0.00 to 20.00 mS/cm,
0.00 to 20.00 mS/cm,
0.0 to 200.0 mS/cm
specific resistance: 5.0 to 100.0 kΩ*cm,                 0 to 200 kΩ*cm,
0.50 to 10.00 kΩ*cm,              
0 to 2,000 kΩ*cm
50 to 1,000 Ω*cm,
5.0 to 100.0 Ω*cm
TDS: 0.0 to 200.0 mg/l,                     0.0 to 200.0 mg/l,
0 to 2,000 mg/l                         
0.00 to 20.00 mg/l
salinity: 0.0 to 70.0 (PSU)
temperature measurement: -5.0°C to +140.0°C (device), please note permissible temperature of the measuring cell



measuring cell:
2-pole measuring cell, conductivity measuring cell with integrated temperature sensor.
Cell constant determined and preset at the factory.
accuracy:
(at nominal temperature = 25°C)
conductivity: +0.5 % of measured value +0.3 % FS (-RW: +1 % of measured value +0.3 % FS)
temperature: +0.2°C +1 digit
connection of measuring cells: 7-pole diode socket
cell constant: K = 0.30 to 1.20, adjustable (-RW: 0.03 to 0.12)
temperature compensation:
(customer selectable)
off: no compensation
Lin: linear compensation (0.3 to 3.0 %/K)
nLF: non-linear compensation for natural
         water according to EN27888 (ISO
         7888)
at salinity: automatic according to IOT

display: approx. 10 mm high, 4-digit LCD-display
output signal: 4 mA to 20 mA (2-wire), standard
0 V to 1 V or 0 V to 10 V (3-wire), surcharge
galvanic isolation: input galvanically isolated
auxiliary power: 12 V DC to 30 V DC
(for option 0 V to 10 V: 18 V DC to 30 V DC)
polarity protection: 50 V continuous
perm. burden: (at 4 mA to 20 mA): RA[Ω] (Uv [V] - 12 V) / 0.02 A
per. load: (at 0 V to 10 V):  RL > 3,000 Ω
working temperature: -25°C to +50°C (transducer)
0°C to +80°C (measuring cell)
storage temperature: -25°C to +70 °C
electrical connection: angle connector according to EN 175301-803/A (IP 65)
housing:ABS (IP65)  except electrode connection sockets
dimensions:82 x 80 x 55 mm, without angle plug and socket
warranty:12 months
mounting:with fixing holes for wall mounting, ounting distance: 70 x 50 mm (W x H)

 

catalogue page as .pdf:
instruction manual as .pdf:

 

 

 

Empfohlenes Zubehör | Weitere Artikel

Leitfähigkeitskontrolllösung | GKL 100

Leitfähigkeitskontrolllösung | GKL 100

9,15 EUR

Leitfähigkeitskontrolllösung | GKL 101

Leitfähigkeitskontrolllösung | GKL 101

57,80 EUR

Leitfähigkeitskontrolllösung | GKL 102

Leitfähigkeitskontrolllösung | GKL 102

9,15 EUR

Aufsteck-Gewindeadapter | PG 13.5

Aufsteck-Gewindeadapter | PG 13.5

6,90 EUR

Gewindeadapter | GWA1Z

Gewindeadapter | GWA1Z

23,30 EUR

Ersatzmesszelle, 2-polig | LFE 202

Ersatzmesszelle, 2-polig | LFE 202

166,50 EUR

Ersatzmesszelle, 2-polig | LFE 210

Ersatzmesszelle, 2-polig | LFE 210

461,00 EUR

Ersatzmesszelle, 2-polig | LFE 220

Ersatzmesszelle, 2-polig | LFE 220

249,00 EUR

Ersatzmesszelle, 2-polig | LFE 230

Ersatzmesszelle, 2-polig | LFE 230

233,00 EUR

Ersatzmesszelle, 2-polig | LFE 240

Ersatzmesszelle, 2-polig | LFE 240

199,00 EUR

Verbindungskabel | VKMU-M12

Verbindungskabel | VKMU-M12

84,80 EUR

Warenkorb

Sie haben noch keine Artikel in Ihrem Warenkorb.

Warenkorb »

Herzlich willkommen

E-Mail-Adresse:
Passwort:
Passwort vergessen?

Top Artikel