standard pH- and ORP single rod electrodes

standard pH- and ORP single rod electrodes


195,50 EUR

 inkl. 19 % USt  -> Preis zzgl. Versandkosten

Lieferzeit bzw. Fertigungszeit variiert - bitte erfragen!

Art.Nr.: PH REDOX
measuring cells/electrodes:
AL70pH-00: pH electrode 2...13 pH; -5...+80°C; max. 3 bar:
L9080: pH electrode 0...12 pH; -30...+80°C; max. 6 bar (+ 325,50 EUR) :
EGA142-VP: pH electrode 0...14 pH; -5...+80°C; max. 6 bar (+ 93,50 EUR) :
EGAT173-VP-X: pH electrode 0...14 pH; -5...+80°C; max. 6 bar (+ 205,50 EUR) :
SL81-120pHt-VP: pH electrode 0...14 pH; 0...+135°C; max. 10 bar (+ 340,50 EUR) :
AL79Pt-00: ORP electrode 2...13 pH; -5...+80°C; max. 3 bar (+ 9,50 EUR) :
PT8281HD-00: ORP electrode 2...13 pH; -5...+100°C; max. 10 bar (+ 292,50 EUR) :

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Produktbeschreibung


general information:


  • pH and ORP single rod electrodes are supplied with a protective cap which is filled with a 3 mole KCL solution. The electrodes can be stored up to 1 year in this state. Therefore, the protective cap should only be removed immediately before installation and use.
  • The shaft of the single rod electrodes is made of glass and is fragile. It must necessarily be ensured that the tips do not strike against anything during installation.
  • Due to deviation of the characteristics from the ideal line, for the precise measurements it is necessary to calibrate the electrode at start-up and then in regular time intervals.
  • A combined electrode must not drain at the tip, otherwise it becomes useless. For regeneration the active area of the electrode is immersed into a 3 mole KCL storage solution for approximately 24 hours. After that calibration is necessary, because the zero point and slope may have shifted.
  • In dirty and protein-containing media a cleaning of the electrodes is necessary occasionally. We offer a special cleaning solution for this purpose. The electrodes must be rinsed off with water after cleaning.
  • the reference system is silver / silver chloride (Ag / AgCl) electrode zero point pH 7.00
  • mounting length 120 mm
  • process connection PG 13.5

 

specifications of single rod electrodes:

AL70pH-00:
pH; application area water 2...13 pH, working temp. -5°C...+80°C; max. pressure 3 bar; connection S7; reference electrolyte gel; diaphragm ceramic; min. conductivity of medium 50 μS/cm; installation position 10...170°


L9080: pH; application area ultrapure water, boiler feed water 0...12 pH; working temp. -30°C...+80°C; max. pressure 6 bar; connection S7; reference electrolyte liquid; diaphragm ceramic; min. conductivity of medium <1 μS/cm; installation position 10...170°

EGA142-VP: pH; application area water, swimming pool, waste water 0...14 pH; working temp. -5°C...+80°C; max. pressure 6 bar; temperature sensor Pt1000; connection VP; reference electrolyte gel; diaphragm ceramic; min. conductivity of medium 100 μS/cm; installation position 30...150°

EGAT173-VP-X: pH; application area heavily contaminated waste water, electroplating 0...14 pH; working temp. -5°C...+80°C; max. pressure 6 bar; temperature sensor Pt1000; connection VP; reference electrolyte gel; diaphragm cut; min. conductivity of medium 50 μS/cm; installation position 30...150°
 
SL81-120pHT-VP: pH; application area food (sterilized), water, waste water 0...14 pH; working temp. 0°C...+135°C; max. pressure 10 bar; temperature sensor Pt1000; connection VP; reference electrolyte gel; diaphragm ceramic; min. conductivity of medium 50 μS/cm; installation position 10...170°
 
AL79Pt-00: ORP; application area environmental technology, desinfection 2...13 pH; working temp. -5°C...+80°C; max. pressure 3 bar; connection S7; reference electrolyte Polymer (Referid); diaphragma ceramic; min. conductivity of medium 50 μS/cm; installation position 10...170°
 
Pt8281HD-00: ORP; application area environmental technology, desinfection 2...13 pH; working temp. -5°C...+100°C; max. pressure 10 bar; connection S7; reference electrolyte Polymer (Referid); diaphragm KPG; min. conductivity of medium 50 μS/cm; installation position 10...170°
 
important information!
pH and Redox electrodes have a limited service life. This depends on the usage conditions, such as medium, pressure, and temperature, and can vary from a few weeks to several years. There are special cases in which a service life of only a few days can be achieved due to extreme usage conditions. The characteristic curve and adjusting time of the electrode shift due to ageing. The resulting error can be compensated due to a certain degree of ageing by recalibration in combination with downstream electronics (e.g. UNICON-pH converter).

pH and Redox single rod electrodes are consumable articles and not subject to the normal guarantee. No returns or exchanges are accepted.

Our offer also includes the free technical advice on the selection of the optimal pH and ORP single rod electrodes. In addition to the listed standard electrodes, we also provide versions specially adapted to the respective usage conditions.

 

For further information p.r.t. data sheet:

 


 


 

 