pH and ORP panelmeter | pH9648

pH and ORP panelmeter | pH9648


701,00 EUR

 inkl. 19 % USt  -> Preis zzgl. Versandkosten

Lieferzeit bzw. Fertigungszeit variiert - bitte erfragen!

Art.Nr.: PH9648
terminal block A:
13: input pH/ORP electrode, temperature compensation with Pt100/Pt1000:
terminal block B:
00: not set:
2R: 2 relay outputs (+ 88,70 EUR) :
2T: 2 electronic outputs (+ 88,70 EUR) :
terminal block C:
00: not set:
2R: 2 relay outputs (+ 88,70 EUR) :
2T: 2 electronic outputs (+ 88,70 EUR) :
AO: analog output 0/4 to 20 mA and 0/2 to 10 V DC (+ 158,50 EUR) :
2A: 2 analog outputs 4 to 20 mA, passive (+ 211,00 EUR) :
terminal block D, auxiliary voltage:
0: 230 V AC ±10 % 50-60 Hz:
1: 115 V AC ±10 % 50-60 Hz (+ 17,80 EUR) :
4: 24 V AC ±10 % 50-60 Hz (+ 17,80 EUR) :
5: 24 V DC ±15 % (+ 35,20 EUR) :
options MA:
unit (imprint in the unit field) :

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Produktbeschreibung


general information:

The pH and ORP panelmeter pH9648 is suitable for pH and ORP measurements in food technology, in chemistry, in the pharmaceutical sector and in sewage water technology. The measuring device operates with all common pH and ORP electrodes. It is recommended to connect the impedance converter pH40 for longer cable lengths >5 m.

  • LED display 14.2 mm red
  • measuring range programmable in the range -1 pH to +15 pH / ±1,500 mV
  • temperature compensated via P100/Pt1000 sensor
  • analog output 0/4 mA to 20 mA or 0/2 V to 10 V for pH/ORP
  • max. 4 alarm outputs relay or transistor


specifications:

auxiliary energy

auxiliary voltage: 230 V AC ±10 %; 115 V AC ±10 %;
24 V AC
±10 % or 24 V DC ±15 %
power consumption: max. 3.5 VA, with analog output 5 VA
operating temperature: -10°C to +55°C
CE conformity:EN 61326-1:2013, EN 60664-1:2007


input
pH/ORP
measuring range:-1.00 pH to +15.00 pH or -1,500 mV to +1,500 mV
Ri:>1012 Ω
input current:<10-12 A
basic accuracy:0.2 % of measured value, ±2 digit
calibration limits pH:electrode zero point 4.00 pH to 10.00 pH
slope 40.0 mV/pH to 70.0 mV/pH
ORP offset:±200 mV
types of calibration:- 1- or 2-point calibration
buffer selection:
- Schott
- WTW
- Ingold (Mettler Toledo)
- buffer acc. to DIN 19266
- or manual input of an arbitrary buffer
- data entering of zero point and slope
- ORP offset
temperature
temperature probe:Pt100 or Pt1000, (2- or 3-wire connection)
unit:programmable °C, °F
measuring range:-40.0°C to +160.0°C (-40.0°F to +320.0°F)
basic accuracy:±0.1 %, ±1 digit
transmitter supply:24 V DC, Ri approx. 150 Ω, max. 50 mA (25 mA with 4 relay outputs)


display
display:LED red, 14.2 mm
additional display:LED 2-digit red, 7 mm
(indication of parameter and switching state)


output
relay SPDT:<250 V AC <250 VA <2 A,
<300 V DC <50 W <2 A
transistor:<35 V AC/DC, max.100 mA,
with electronical current limit
analog output:active: 0/4 mA to 20 mA burden ≤500 Ω; 0/2 V to 10 V
burden >500 Ω, galv. isolated
output switches automatically (burden dependent)
passive: 4 mA to 20 mA,
ext. burden = RA[Ω]≤ (Ub - 5 V) ÷ 0.02 A;
auxiliary voltage 5 V DC to 30 V DC
accuracy:0.1 %


housing
housing:panel mounting DIN 96 x 48,
material PA6-GF; UL94V-0
dimensions:front 96 x 48 mm, mounting depth 100 mm
weight:max. 390 g
connection:clamp terminals, 2.5 mm2 single wire, 1.5 mm2 fine-wire
AWG14
ingress protection:front IP65, terminals IP20, BGV A3





For further details p.r.t. data sheet:




connection diagram:





instruction manual as .pdf:


 

 

 