construction type:
1: output 4..20 mA for pH/ORP, 2 electronic alarm outputs:
2: as 1, but 2nd measuring range for pH/ORP, output 4..20 mA for temperature, monitoring of the glass impedance, reference electrode and the calibration interval (+ 176,50 EUR) :
type of installation:
01: head mounting, directly on measuring cell:
02: field mounting, connection of the sensor with seperate cable:
reference system:
3: all systems with electrode zero point pH7.00 e.g. silver/silver chloride:
temperature compensation:
13: Pt100/Pt1000 sensor via software selectable:

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Produktbeschreibung


general information:

The pH and ORP converter UNICON-pH is suitable for pH and ORP measurement in food technology, chemistry within pharma- ceutical and sewage-water technology. The converter works with all common pH- and ORP electrodes.

  • field or head mounting
  • measuring range programmable -1..+15 pH / ±1,500 mV
  • temperature compensation via P100/Pt1000 sensor
  • output 4 to 20 mA for pH and temperature
  • 2 alarm outputs, transistor


specifications:

auxiliary energy
auxiliary voltage: 14 to 30 V DC, 2-wire
operating temperature: 0°C to +55°C
CE conformity:EN 61326-1:2013


input
pH/ORP
output signal:
4 to 20 mA
burden:                                       
RA[Ω]≤ (UB-14 V) ÷ 0.02 A
measuring range:-1.00..+15.00 pH or -1,500..+1,500 mV
Ri:>1012 Ω
input current:<10-12 A
accuracy:0.2 % vom measuring value, ±2 digit
electrode zero point:7.00 pH
slope:30 to 80 mV/pH
ORP setup:±200 mV
calibration mode:- 1- or 2-point-calibration
buffer selection possible:
- Schott
- WTW
- Ingold (Mettler Toledo)
- buffer acc. to DIN 19266
- or manual buffer input
- data entering for zero point and slope
- ORP setup
temperature
output signal:4 to 20 mA
burden:RA[Ω]≤ (UB-14 V) ÷ 0.02 A
temperature sensor:Pt100 or Pt1000 (2-wire)
unit:programmable °C, °F
measuring range:-40.0°C to +160.0°C (-40.0°F to +320.0°F)
accuracy:±0.1 %, ±1 digit
glass impedance:0 to 1 GΩ (temperature compensated)
detection range:0.001 to 2 GΩ (non compensated)
accuracy:±20 %
reference impedance:0 to 100 kΩ (non compensated)
monitoring of the calibration interval:1 to 1,000 days


displayLCD dot matrix, 3.8 mm characters
2 lines 16 characters each


alarm outputs
transistor:14 to 30 V DC, max. 60 mA, short-circuit-proof
voltage drop:<2 V


range switch
Ri:>10 kΩ
MB1 active:U = 0 to 3 V DC
MB2 active:U = 12 to 30 V DC


housing
type of housing:head-field case
material:housing polyamide fiber glass
PA6-GF/GK 15/15, front foil polyester
dimensions:100 x 100 x 60 mm (W x H x D)
weight:max. 360 g
connection:screw terminals pressure plate, 2.5 mm2 flexible, 4 mm2 single wire connection cable
ingress protection:IP65, terminals IP20 acc. to BGV A3





For further details p.r.t. data sheet:




instruction manual as .pdf:


 

 

pH- and ORP converter | UNICON®-pH
 

Empfohlenes Zubehör | Weitere Artikel

Anschlussleitungen zur pH- und Redox-Messung | S7

Anschlussleitungen zur pH- und Redox-Messung | S7

84,50 EUR

Warenkorb

Sie haben noch keine Artikel in Ihrem Warenkorb.

Warenkorb »

Herzlich willkommen

E-Mail-Adresse:
Passwort:
Passwort vergessen?

Top Artikel