Deutsch  English 


digital fine manometer for over / under and differential pressure | GMH 3181-07

digital fine manometer for over / under and differential pressure | GMH 3181-07


492,00 EUR

 inkl. 19 % USt  -> Preis zzgl. Versandkosten

Lieferzeit in der Regel ca. 1 Woche

Art.Nr.: GMH3181-07
sensor:
HS: higher sensor accuracy (+ 80,50 EUR) :
options GR :
Ex-qualification: EX II 2 G Ex ib IIC T4 Gb (+ 279,00 EUR) :

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Produktbeschreibung


device -10.0 mbar to +350.0 mbar (±350.0 mbar, measuring range possible by changing the pressure connection ports), logger


general information:

  • integrated pressure sensor
  • stable metal connection pins
  • tare function / zero point offset
  • model with EX protection available
  • logger functions
  • low power logger mode
  • averaging function
  • controlling function


specifications:

measuring range:-10.0 mbar to +350.0 mbar
overload:max. 1 bar
resolution:0.1 mbar
additional pressure units:bar, Pa, kPa, MPa, PSI, mmHg, mH2O
accuracy (typ. values):hysteresis and linearity: ±0.2 % FS (±0.1 % FS at option "higher accuracy")
temperature influence from 0 to 50°C: ±0.4 % FS
option higher accuracy available: yes
pressure connections:2
display: 2x 4½-digit LCD
sensor:
Piezoresistive differential pressure sensor internally built into the instrument. Suitable for air and non-aggressive gases.
(Note: not suited for water!)

pressure connection: 2 universal pressure ports for 6 x 1 mm (4 mm internal diameter of tube) or 8 x 1 mm (6 mm internal diameter of tube) plastic tubes
output: interface or AAG
serial interface: yes
analog output:0 V to 1 V, freely scalable (resolution 12 bit)
power supply:
9 V battery, mains adapter
sensor adjustment:digital offset  and scale input
peak value memory:≥1 ms
measuring cycle:        
"slow": 4 measurements / s
"fast": (with filter): ≥1,000 measurements / s
„peak-detect“ (
peak value memory): ≥1,000 measurements / s
The min- / max- value memory stores unfiltered pressure peaks ≥1 ms.
averaging function:Integrates the meas. values during a selectable period of time and then calculates the average display value.
low power logger mode:(only in measuring cycle „slow“) Only one measurement carried out at the end of the respective logger cycle. The battery life is considerably prolonged. For long-term recordings (e.g. leaktest).
controlling function:with the help of the switching module GAM3000 (optionally) external devices can be controled (switch on/off) or alarm monitored
logger functions:- manual: 99 data sets
- cyclic: 10,000 data sets (max. 64 recording sequences),
adjustable cycle time: 1 s to 3,600 s
battery life:approx. 500 h (slow mode)
approx. 120 h (fast = 1,000 Hz)
working conditions:-25°C to +50°C, 0 % to +95 % r.h. (non-condensing)
construction type EX: -10°C to +50°C, 0 % to 95 % r.h. (
non-condensing)
housing:142 x 71 x 26 mm (H x W x D) (without pressure connection pin - pin approx. 16 mm protruding at front side of device), impact-resistant ABS, membrane keypad, transparent panel, integrated pop-up clip
weight:approx. 170 g
construction type EX: approx. 210 g (incl. leather case)



note to EX-design types - technical changes compared to standard instruments (valid for all GMH31xx-EX):

EX qualification: II 2 G Ex ib IIC T4 Gb
ref. document: EPS 09 ATEX 1 227 X
standards:
the device meets the standards for electric resources in explosion endangered areas according to EN 60079-0 : 2012, EN 60079-11 : 2012
sensor:
(GMH 3111-EX, GMH 3151-EX, GMH 3156-EX) All GMSD / MSD sensors with option „EX-type“ can be used.
interface:
suitable interface adapter are USB 3100 N, GRS 3100 and GRS 3105
Note: The operation of the interface and the analog output is not allowed within the EX area!
working temperature: -10°C to +50°C
power supply: 9 V battery, mains adapter
Note:
The operation of the mains adapter is not allowed within the EX area! Only  adapters of the type GNG10/3000 can be used.
alarm function:
(GMH 3151-EX, GMH 3156-EX, GMH 3181-EX) The device is without a horn, in the alarm settings only the parameter „no.so“ und „off“ are adjustable.
scope of supply:
device is delivered with leather case




catalogue pages as .pdf:






instruction manual as .pdf:


 

 

 

Empfohlenes Zubehör | Weitere Artikel

Geräte-Schutztasche | ST-R2

Geräte-Schutztasche | ST-R2

47,60 EUR

Koffer | GKK 3000

Koffer | GKK 3000

25,70 EUR

Steckernetzgerät | GNG 10/3000

Steckernetzgerät | GNG 10/3000

65,10 EUR

Schnittstellen-Konverter | GRS 3100

Schnittstellen-Konverter | GRS 3100

84,60 EUR

USB Schnittstellen-Konverter | USB 3100N

USB Schnittstellen-Konverter | USB 3100N

84,60 EUR

ISO-Kalibrierschein Druck | WPD 5

ISO-Kalibrierschein Druck | WPD 5

140,10 EUR

ISO-Kalibrierschein Druck | WPD 10

ISO-Kalibrierschein Druck | WPD 10

229,00 EUR

Doppeltülle | GDZ-8

Doppeltülle | GDZ-8

2,90 EUR

Schlauchschelle | GDZ-18

Schlauchschelle | GDZ-18

1,70 EUR

T-Stück | GDZ-21

T-Stück | GDZ-21

2,90 EUR

Logger-Software | GSOFT 3050

Logger-Software | GSOFT 3050

105,20 EUR

Analog-Ausgang-Kabel | AAG2M

Analog-Ausgang-Kabel | AAG2M

35,00 EUR

Warenkorb

Sie haben noch keine Artikel in Ihrem Warenkorb.

Warenkorb »

Herzlich willkommen

E-Mail-Adresse:
Passwort:
Passwort vergessen?

Top Artikel