set GMH 3331-TFS-GOF consisting of:
- humidity/temperature and flow rate measuring device GMH 3351 (direct successor of GMH 3350)
- humidity/temperature sensor TFS 0100 E
- surface temperature probe GOF 400 VE
- case GKK 3500
The GMH 33xx devices are universal precision hygrometers/thermometers with additional thermocouple input in one. The plug-in probes are exchangeable without recalibration, because the calibration data are stored on an integrated memory (TFS...). The thermocouple input T2 has been optimized to quickly acquire surface temperatures e.g. to indicate the dewpoint distance directly.
- calculation of dewpoint temperature, dewpoint distance and enthalpy
- additional temperature input (type K)
- logger function
applications:
- heating / ventilation air conditioning (HVAC)
- indoor air, meteorology, laboratory, research and teaching
- energy assessment / optimization of buildings
- cause study at structural damage
measuring range: |
relative humidity: 0.0 % to 100.0 % r.h. ambient temperature: -40.0°C to +120.0°C (depending on TFS-probe) surface temperature: -80.0°C to +250.0°C flow rate: probes upon request |
resolution: | 0.1 % r.h., 0.1°C or 0.1°F, 0.01 m/s |
accuracy (device) (±1 digit) (at nominal temperature = 25°C): | relative humidity: ±0.1 % ambient temperature (Pt1000): ±0.2 % surface temperature (type K): ±0.5 % of measured value ±0.5°C |
sensors: | no calibration required for exchange of humidity/temperature or flow rate probe (upon request) |
sensor connection: | 6-pole screened Mini-DIN-socket |
type K connection: | for miniature flat-pin plug |
display: | two 4½-digit LCD displays (12.4 mm or 7 mm high), as well as additional functional arrows |
working temperature: | -25°C to +50°C |
relative humidity: | 0 % to 95 % r.h., non-condensing |
storage temperature: | -25°C to +70°C |
control elements: | 6 membrane keys |
interface: | serial interface, direct connection to RS232 or USB interface of a PC via electrically isolated interface converters GRS 3100 or GRS 3105 resp. USB 3100 N (accessories) |
power supply: | 9 V battery, as well as additional d.c. connector for external 10.5-12 V direct voltage supply (suitable power supply unit: GNG10/3000) |
battery life: |
approx. 120 h (with TFS0100) |
calculation of dewpoint: |
based upon humidity and temperature |
calculation of dew point distance: | by means of a surface measurement |
calculation of enthalpy: | thermal content h of the air |
type K-temperature measurements: | any standard type K probe (type NiCr-Ni) is connectable, recommendation: GOF 400 VE, a correction value can be set to compensate losses of heat transfer |
flow measurements: | two different systems for averaging are integrated: continuous averaging: continuous display of the average value averaging upon request: by starting the current measuring value will be displayed, as soon as the averaging time has expired the average value will be displayed, the device is in HOLD mode selectable averaging time: 1 s to 30 s |
housing: | impact-resistant ABS plastic housing, membrane keyboard, transparent panel, integrated pop-up clip |
dimensions: | 142 x 71 x 26 mm (H x W x D) |
weight: | approx. 160 g (incl. battery) |
measuring ranges: | humidity: 0.0 % to 100.0 % r.h. (recommended range of application: 10 % to 90 % r.h.) temperature: -40.0°C to +120.0°C (please note the working temperature of the electronics) |
accuracy (at nominal temperature = 25 °C): | humidity: ±2.5 % r.h. (in the range 10 % to 90 % r.h.) temperature: ±0.5°C |
sensors: | humidity: capacitive polymer humidity sensor temperature: Pt1000, DIN class AA |
electronics: | PC board with amplifier and data memory for sensor data (calibration, etc.) integrated in probe handle |
working temperature: | handle and electronics: -25°C to +60°C sensor head and tube: -40°C to +100°C (short-term up to +120°C) |
relative humidity: | 0 % to +100 % r.h. |
dimensions: | probe tube: Ø 14 x 119 mm, plastic handle: Ø 19 x 135 mm, approx. 1.2 m PVC-connection cable with 6-pole Mini-DIN plug |