combined probe for illuminance and UVA irradiance | LP-471 P-A
582,00 EUR
inkl. 19 % USt -> Preis zzgl. Versandkosten
Lieferzeit bzw. Fertigungszeit variiert - bitte erfragen!
Art.Nr.: LP-471 P-AProduktbeschreibung
- combined probe LP 471 P-A with two sensors for the measurement of illuminance and UVA irradiance
- destruction-free material measurement according to ISO 3059:2001
general information:
Combined probe for the measurement of illuminance (lux) with photopic standard sensitivity and irradiance (μW/cm2) in the UVA spectral range (315 nm to 400 nm, with peak at 360 nm). Both sensors are equipped with a diffusor for correction according to the cosine law.
Measuring range for illuminance: 0.10 lux to 200·103 lux
Measuring range for irradiance: 1.0 mW/m2 to 2,000 W/m2.
This probe provides a balanced ratio between UVA irradiance and illuminance in μW/lumen (quantity of interest in museums). The probe is equipped with a SICRAM module and 2 m long cable.
application areas:
Museums (see regulation), destruction-free testing (see regulation), for casting and welding control, museum object damage (CIE 157) for paper and wood safety.
specifications:
illuminance
measuring range and resolution (lux): |
measuring range: 0.10...199.99 resolution: 0.01 measuring range: ...1,999.9 resolution: 0.1 measuring range: ...19,999 resolution: 1 measuring range: ...199.99·103 resolution: 0.01·103 |
|
spectral range: | in agreement with a standard photopic curve V(λ) | |
α (temp. coefficient) f6 (T) | <0.05 % K | |
calibration uncertainty: | <4 % | |
f'1 (in agreement with photopic response V(λ)): | <6 % | |
f2 (response according to the cosine law) | <3 % | |
f3 (linearity): | <1 % | |
f4 (instrument reading error): | <0.5 % | |
f5 (fatigue): | <0.5 % | |
class: | B | |
drift after 1 year: | <1 % | |
working temperature: | 0°C to +50°C | |
reference standards: | CIE n.69 – UNI 11142 |
UVA irradiance:
measuring range and resolution (µW/cm2): |
measuring range: 0.10...199.99 resolution: 0.01 measuring range: ...1,999.9 resolution: 0.1 measuring range: ...19,999 resolution: 1 measuring range: ...199.99·103 resolution: 0.01·103 |
|
spectral range: | 315 nm to 400 nm (peak 360 nm) | |
calibration uncertainty: | <5 % | |
f2 (response according to the cosine law) | <6 % | |
f3 (linearity): | <1 % | |
f4 (instrument reading error): | +1 digit | |
f5 (fatigue): | <0.5 % | |
drift after 1 year: | <2 % | |
working temperature: | 0°C to +50°C |
catalogue page as .pdf: |
Empfohlenes Zubehör | Weitere Artikel
Photo- und Radiometer | HD-2302-0339,00 EUR |
|
Photo-Radiometer | HD21020,00 EUR |