  • combined probe LP 471 P-A with two sensors for the measurement of illuminance and UVA irradiance
  • destruction-free material measurement according to ISO 3059:2001

general information:

Combined probe for the measurement of illuminance (lux) with photopic standard sensitivity and irradiance (μW/cm2) in the UVA spectral range (315 nm to 400 nm, with peak at 360 nm). Both sensors are equipped with a diffusor for correction according to the cosine law.
Measuring range for illuminance: 0.10 lux to 200·10
3 lux
Measuring range for irradiance: 1.0 mW/m2 to 2,000 W/m2.
This probe provides a balanced ratio between UVA irradiance and illuminance in μW/lumen (quantity of interest in museums). The probe is equipped with a SICRAM module and 2 m long
cable.


application areas:

Museums (see regulation), destruction-free testing (
see regulation), for casting and welding control, museum object damage (CIE 157) for paper and wood safety.


specifications:

illuminance

measuring range and resolution (lux): measuring range: 0.10...199.99       resolution: 0.01
measuring range: ...1,999.9              resolution: 0.1
measuring range: ...19,999               resolution: 1
measuring range: ...199.99·103       resolution: 0.01·103
spectral range:in agreement with a standard photopic curve V(λ)

α (temp. coefficient) f6 (T)<0.05 % K
calibration uncertainty:<4 %
f'1 (in agreement with photopic response V(λ)):<6 %
f2 (response according to the cosine law)<3 %
f3 (linearity):<1 %
f4 (instrument reading error):
<0.5 %

f5 (fatigue): <0.5 %
class:B
drift after 1 year:<1 %
working temperature:0°C to +50°C
reference standards:CIE n.69 – UNI 11142


UVA irradiance:

measuring range and resolution (µW/cm2): measuring range: 0.10...199.99       resolution: 0.01
measuring range: ...1,999.9              resolution: 0.1
measuring range: ...19,999               resolution: 1
measuring range: ...199.99·103       resolution: 0.01·103
spectral range:315 nm to 400 nm (peak 360 nm)

calibration uncertainty:<5 %
f2 (response according to the cosine law)<6 %
f3 (linearity):<1 %
f4 (instrument reading error):
+1 digit

f5 (fatigue): <0.5 %
drift after 1 year:<2 %
working temperature:0°C to +50°C



catalogue page as .pdf:

 

 

 

 

Empfohlenes Zubehör | Weitere Artikel

Photo- und Radiometer | HD-2302-0

Photo- und Radiometer | HD-2302-0

339,00 EUR

Photo-Radiometer | HD2102

Photo-Radiometer | HD2102

0,00 EUR

Warenkorb

Sie haben noch keine Artikel in Ihrem Warenkorb.

Warenkorb »

Herzlich willkommen

E-Mail-Adresse:
Passwort:
Passwort vergessen?

Top Artikel