723: Pt100 with measuring transducer 4 to 20 mA:
measuring range:
1: measuring range -10 to +40°C:
2: measuring range 0 to +50°C:
3: measuring range 0 to +100°C:
4: measuring range 0 to +150°C - temperatures >100°C max. 30 min:
B: measuring transducer with special measuring range in °C - please state the special measuring range separately e.g.: 0..75°C or -20..+30°C, mind the minimum range of 50°C. (+ 25,60 EUR) :
please enter special range here:
electrical connection:
2: GTL723 2-wire, 4 to 20 mA, M12 plug:
pipe wall adjustment for stainless steel type pipes:
0: not active:
1: without heat-conducting paste:
2: with heat-conducting paste:
options GR :
WZ2.2: factory certificate 2.2 (+ 33,80 EUR) :
APZ3P: acceptance test certificate 3.1 with 3 measuring points (0°C / 70°C + 1 test point freely selectable) (+ 164,50 EUR) :
01: high temperature version - max. permanent temperature +160°C (+ 106,30 EUR) :

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Produktbeschreibung


temperature in "Hygienic Design"

model GTL 723: clamp-on temperature sensor, Pt100 with measuring transducer 4 mA to 20 mA


general information:

Clamp-on temperature sensors GTL720 and GTL723 are specified to measure temperatures without media contact. The measuring tip is directly located at the pipe wall and is fixed to the pipe by the clamp-on adapter. This measuring process provides a high accuracy and a fast response time, which is often better than measuring probes with media contact.

  • simple mounting via clamp-on adapter, without media contact
  • high accuracy even without heat-conducting paste
  • fast response time
  • replacing/cleaning of the sensor without process interruption
  • measuring transducer 4 mA to 20 mA, 2-wire connection
  • measuring transducer programmable via GTL Configuration tool


specifications:

temperature sensor: Pt100, class A acc. to DIN EN 60751
measuring range: -20°C to +100 °C, short-time +160°C <30 min,
(option 01 = max. +160°C permanent temperature) programmable, minimal measuring span 50°C
ambient temperature: -20°C to +60°C
storage conditions: with yellow protective cap
temp.: -20°C to +70°C
max. rel. humidity 70 %
ingress protection: IP67 (in connection with mounted M12 plug)
electrical connection: round plug 4-pole M12x1
tightening torque 0.6 Nm
auxiliary voltage Ub: 10 V DC to 30 V DC, 2-wire connection
error indication: programmable
load: (Ub – 10 V) /23 mA
response time/accuracy *:measurement without heat-conducting paste, medium temperature 120°C
response time
T90: approx. 10 s
accuracy:
  up to 2.5 % f.s. without pipe wall adjustment
  up to 0.6 % f.s. with pipe wall adjustment

measurement with heat-conducting paste, medium temperature 120°C
response time T90: approx. 3 s
accuracy:
 
up to 1 % f.s. without pipe wall adjustment
  up to 0.2 % f.s. with pipe wall adjustment
 

temperature coefficient: 0.02 %/°C
output:4 mA to 20 mA 
material:sensor
spring: 1.4310
sensor insert: PEEK
sensor tip: 935er silver
lid: 1.4305
M12 plug: PA/gold plated contacts
weight: 17 g

clamp-on adapter
adapter: 1.4405
housing: 1.4305
adapter insert: silicone HTV/PTFE
weight:
frame size 1: 120 g
frame size 2: 170 g
frame size 3: 395 g
frame size 4: 955 g


* Measurement results depending on the mounting situation.


Note: To purchase the whole measuring system it is necessary to order the clamp-on sensor and the clamp-on adapter.





For further details p.r.t. data sheet:



instruction manual as .pdf:

 

 

 

Empfohlenes Zubehör | Weitere Artikel

Rohrleitungsadapter | RLA

Rohrleitungsadapter | RLA

161,50 EUR

Warenkorb

Sie haben noch keine Artikel in Ihrem Warenkorb.

Warenkorb »

Herzlich willkommen

E-Mail-Adresse:
Passwort:
Passwort vergessen?