Deutsch  English 


waterproof portable pH / redox measuring device incl. electrode | GMH 5530-G135

waterproof portable pH / redox measuring device incl. electrode | GMH 5530-G135


487,00 EUR

 incl. 19 % VAT  excl. shipping costs

delivery time usually 0-4 working days for standard construction type

Product.Nr.: GMH5530-G135

Bitte beachten Sie stets die Bestellhinweise auf den einzelnen Datenblättern!

Product Description


waterproof measuring device for pH, ORP, temperature GMH 5530 with pH electrode GE 135 (Pt1000)


general information:

  • GLP features (good laboratory practice)
  • large dual display with background illumination
  • high resolution (0.001 pH / 0.1 mV)
  • incl. calibration protocol


applications:

  • measurements in water bodies, fish keeping, aqua farming
  • monitoring of drinking water and processes, soil measurements
  • food production and monitoring
  • laboratory: Medicine, pharmaceutics, chemistry
  • quality management


specifications device GMH 5530:

measuring ranges: pH: -2.000 pH to 16.000 pH (resolution selectable)
redox/mV: -2,000.0 mV to +2,000.0 mV (resolution selectable)
(
based on hydrogen system DIN38404:
-1,792
mVH to +2,207 mVH)
temperature: -5.0°C to +150.0°C; +23.0°F to +302.0°F
rH: 0.0 rH to 70.0 rH

accuracy: pH: ±0.005 pH
redox/mV: ±0.05 % FS (mV or
mVH)
temperature: ±0.2 °C (in the range -5.0°C to +100.0°C)
rH: ±0.1 rH

connections: pH, redox: BNC socket, compatible to standard BNC-plugs
and waterproof BNC-plugs, additional banana jack (4 mm) for separate reference electrode, input resistance: 1012 Ohm
temperature: 2 banana jacks (4 mm) for temperature probes (Pt1000 or NTC 10K)
interface/supply: 4-pole bajonet connector for serial interface and supply (with accessory USB 5100)
operating conditions: -25°C to +50°C; 0 % to 95 % r.h. (non-condensing)
display: two 4 ½ digit 7-segment displays (15 mm and 12 mm)
pH calibration:automatical: 1-, 2- or 3-point calibration, standard
buffer or buffer acc. to DIN19266 (A, C, D, F, G)
manual: 1-, 2- or 3-point
calibration
power supply:2x AAA battery, power consumption: <1.0 mA
battery life:1,000 hours
housing:impact resistant ABS housing with pop-up clip
ingress protection:IP65 / IP67
dimensions:160 x 86 x 37 mm (H x B x T) incl. protective cover
weight:250 g incl. battery and protective cover



further functions:

status display for pH electrode and battery: bar graph display

background illumination: duration adjustable (off, 5 s to 2 min.)

automatic temperature compensation:
In operation mode „pH“ and with connected temperature probe an automatic temperature compensation (ATC) is possible in the range 0°C to +105°C. Without temperature probe a manual input of the temperature is possible.

pH calibration:
1-, 2- or 3- point calibration with characteristic curve for standard buffer, buffer according to DIN19266 (A, C, D, F, G) or manual buffer selection. The temperature dependency of the buffer is compensated automatically when the buffer detection is automatical.
Permissible electrode data: asymmetry: ±55 mV / slope: 45 mV / pH to 62 mV / pH.
The condition of pH-Electrode is checked at each calibration.

redox measurement (ORP):
There are two choices:
„mV“ standard redox or mV measurement
„mVH
conversion to hydrogen system acc. to DIN38404 part 6

rH measurement:
Calculation of the rH value by means of a redox measurement and by manual entering of the pH-value.

calibration interval:
The device asks for a recalibration after a selectable time period (1 to 365 days or inactive).



specifications electrode GE 135:

measuring range: 0 pH to 14 pH
-5°C to +80°C

conductivity:>150 μS/cm
temperature measurement: integr. Pt1000 class B
water-proof: yes
pressure resistant: 5 bar
cable:1 or 2 m, others upon request
electrolyte:gel electrolyte
diaphragm:1x ceramic
large screw-type
electrode shaft:PC, Ø 12 mm x 120 mm
features:submergible, water-proof IP67 (also BNC-plug)
connection:BNC
application areas:on-site measurements, fish farming, beverages, sea water, swimming pool water, drinking water






catalogue pages GMH 5530 as .pdf:





instruction manual GMH 5530 as .pdf:






instruction manual GE 135 as .pdf:


 

 

 

Recommended products

software for acquisition of measurement data | EBS 20M / 60M

software for acquisition of measurement data | EBS 20M / 60M

121,00 EUR

working and calibration set for pH measuring devices | GAK 1400

working and calibration set for pH measuring devices | GAK 1400

60,70 EUR

KCl electrolyte | KCL 3 M

KCl electrolyte | KCL 3 M

9,40 EUR

pepsin cleaning solution | GRL 100

pepsin cleaning solution | GRL 100

10,00 EUR

ORP inspection solution | GRP 100

ORP inspection solution | GRP 100

10,00 EUR

waterproof portable pH / redox measuring device | GMH 5530

waterproof portable pH / redox measuring device | GMH 5530

378,00 EUR

USB interface converter | USB 5100

USB interface converter | USB 5100

128,40 EUR

silicone protection cover | K 50

silicone protection cover | K 50

31,50 EUR

buffer solution | GPH-DOS 4

buffer solution | GPH-DOS 4

23,60 EUR

buffer solution | GPH-DOS 7

buffer solution | GPH-DOS 7

23,60 EUR

buffer solution | GPH-DOS 10

buffer solution | GPH-DOS 10

23,60 EUR

submergible pH electrode (incl. Pt1000 sensor) | GE 135 BNC

submergible pH electrode (incl. Pt1000 sensor) | GE 135 BNC

179,00 EUR

cable for analog output | AAG 5000

cable for analog output | AAG 5000

32,90 EUR

case | GKK 5001

case | GKK 5001

55,30 EUR

case | GKK 2021

case | GKK 2021

127,10 EUR

Shopping Cart

You have no articles inside your cart

Shopping Cart »

Welcome back

E-mail-address:
password:
lost password?

Top products