flow transducer | VHZ-...GA/GK

flow transducer | VHZ-...GA/GK

formerly known as "Volutron"

general information:

The VHZ gearwheel flow meter measures the flow according to the volumetric principle, where a pair of gearwheels is moved proportional to the flow rate. The movement of the gearwheels is measured through the closed housing wall by a sensor. The devices are suitable for viscous, fluid, self-lubricating media, as well as for aqueous fluids such as soaps, pasts, emulsions etc. which have a non-abrasive character. Because of the volumetric operation, the devices are almost completely independent of viscosity.

A push-pull transistor output, an A / B output or a 2-wire output are available as signal output. The push-pull output can optionally be connected as a PNP or an NPN output, and emits a frequency proportional to the flow rate.

The A / B output consists of two push-pull outputs. Their signals are phase-shifted by 90°. Thus, it is possible to determine the direction of flow by using the bidirectionally driven sensor. The 2-wire model represents the pulses by two different currents and has the advantage of reduced wiring effort.


  • ideally suited for viscous media (oils)
  • light and compact construction in an aluminium housing
  • for cost-sensitive applications

specifications:

appliance: flow, measurement, optionally: indication
medium: water, oil
total measuring range:0.02 l/min to 150 l/min H2O or oil
connection: G 1/4 to G 1 internal thread, aluminium or stainless steel
basic data: PN 100 bar to 200 bar, temperature of medium -25°C to +80°C,
optionally -25°C to +120°C (2-wire model DN 10-25)
electrical data:gearwheel volumeter,
3-wire or A / B output: supply voltage 10 V DC to 30 V DC, current consumption approx. 20 mA without load
2-wire:
supply voltage 4.5 V DC to 24 V DC



with integrated evaluation electronic available in the following construction types:

LABO-VHZ
: evaluation electronic with analog output or switching function incl.
FLEX-VHZ:
evaluation electronic with analog output and switching function incl.
OMNI
-VHZ: evaluation electronic with analog output, switching function and display incl.

(see below: recommended products)



 

For further details please see data sheet:

 

 

 

VHZ-...GA/GK:
flow transducer | VHZ-008GA002

flow transducer | VHZ-008GA002


formerly known as "Volutron"

appliance: flow, measurement
medium: water, oil
measuring range:0.02 l/min to 2 l/min H2O or oil
connection: G 1/4 internal thread, aluminium
basic data: PN 200 bar, temperature of medium -25°C to +80°C
electrical data:gearwheel volumeter,
3-wire: supply voltage 10 V DC to 30 V DC, current consumption approx. 20 mA without load
2-wire:
supply voltage 4.5 V DC to 24 V DC



with integrated evaluation electronic available in the following construction types:

LABO-VHZ
: evaluation electronic with analog output or switching function incl.
FLEX-VHZ:
evaluation electronic with analog output and switching function incl.
OMNI
-VHZ: evaluation electronic with analog output, switching function and display incl.

(see below: recommended products)



 

For further details please see data sheet:

 

 

1.776,00 EUR

incl. 19 % VATexcl. shipping costs

 processing time as may be necessary - please ask!

flow transducer | VHZ-008GK002

flow transducer | VHZ-008GK002


formerly known as "Volutron"

appliance: flow, measurement
medium: water, oil
measuring range:0.02 l/min to 2 l/min H2O or oil
connection: G 1/4 internal thread, stainless steel
basic data: PN 160 bar, temperature of medium -25°C to +80°C,
electrical data:gearwheel volumeter,
3-wire: supply voltage 10 V DC to 30 V DC, current consumption approx. 20 mA without load
2-wire:
supply voltage 4.5 V DC to 24 V DC



with integrated evaluation electronic available in the following construction types:

LABO-VHZ
: evaluation electronic with analog output or switching function incl.
FLEX-VHZ:
evaluation electronic with analog output and switching function incl.
OMNI
-VHZ: evaluation electronic with analog output, switching function and display incl.

(see below: recommended products)



 

For further details please see data sheet:

 

 

2.553,00 EUR

incl. 19 % VATexcl. shipping costs

 processing time as may be necessary - please ask!

flow transducer | VHZ-010GA006

flow transducer | VHZ-010GA006


formerly known as "Volutron"

appliance: flow, measurement
medium: water, oil
measuring range:0.1 l/min to 6 l/min H2O or oil
connection: G 3/8 internal thread, aluminium
basic data: PN 160 bar, temperature of medium -25°C to +80°C,
optionally -25°C to +120°C (2-wire model DN 10-25)
electrical data:gearwheel volumeter,
3-wire or A / B output: supply voltage 10 V DC to 30 V DC, current consumption approx. 20 mA without load
2-wire:
supply voltage 4.5 V DC to 24 V DC

Attention: The A / B output requires the use of a 4-pole round plug connector!


with integrated evaluation electronic available in the following construction types:

LABO-VHZ
: evaluation electronic with analog output or switching function incl.
FLEX-VHZ:
evaluation electronic with analog output and switching function incl.
OMNI
-VHZ: evaluation electronic with analog output, switching function and display incl.

(see below: recommended products)



 

For further details please see data sheet:

 

 

1.107,00 EUR

incl. 19 % VATexcl. shipping costs

 processing time as may be necessary - please ask!

flow transducer | VHZ-010GK006

flow transducer | VHZ-010GK006


formerly known as "Volutron"

appliance: flow, measurement
medium: water, oil
measuring range:0.1 l/min to 6 l/min H2O or oil
connection: G 3/8 internal thread, stainless steel
basic data: PN 160 bar, temperature of medium -25°C to +80°C,
optionally -25°C to +120°C (2-wire model DN 10-25)
electrical data:gearwheel volumeter,
3-wire or A / B output: supply voltage 10 V DC to 30 V DC, current consumption approx. 20 mA without load
2-wire:
supply voltage 4.5 V DC to 24 V DC

Attention: The A / B output requires the use of a 4-pole round plug connector!


with integrated evaluation electronic available in the following construction types:

LABO-VHZ
: evaluation electronic with analog output or switching function incl.
FLEX-VHZ:
evaluation electronic with analog output and switching function incl.
OMNI
-VHZ: evaluation electronic with analog output, switching function and display incl.

(see below: recommended products)



 

For further details please see data sheet:

 

 

2.434,00 EUR

incl. 19 % VATexcl. shipping costs

 processing time as may be necessary - please ask!

flow transducer | VHZ-020GA050

flow transducer | VHZ-020GA050


formerly known as "Volutron"

appliance: flow, measurement
medium: water, oil
measuring range:0.5 l/min to 50 l/min H2O or oil
connection: G 3/4 internal thread, aluminium
basic data: PN 160 bar, temperature of medium -25°C to +80°C,
optionally -25°C to +120°C (2-wire model DN 10-25)
electrical data:gearwheel volumeter,
3-wire or A / B output: supply voltage 10 V DC to 30 V DC, current consumption approx. 20 mA without load
2-wire:
supply voltage 4.5 V DC to 24 V DC

Attention: The A / B output requires the use of a 4-pole round plug connector!


with integrated evaluation electronic available in the following construction types:

LABO-VHZ
: evaluation electronic with analog output or switching function incl.
FLEX-VHZ:
evaluation electronic with analog output and switching function incl.
OMNI
-VHZ: evaluation electronic with analog output, switching function and display incl.

(see below: recommended products)



 

For further details please see data sheet:

 

 

1.353,00 EUR

incl. 19 % VATexcl. shipping costs

 processing time as may be necessary - please ask!

flow transducer | VHZO-020GA050

flow transducer | VHZO-020GA050


formerly known as "Volutron"

with sight glass!

appliance: flow, measurement, indication
medium: water, oil
measuring range:0.5 l/min to 50 l/min H2O or oil
connection: G 3/4 internal thread, aluminium
basic data: PN 100 bar, temperature of medium -25°C to +80°C,
optionally -25°C to +120°C (2-wire model DN 10-25)
electrical data:gearwheel volumeter,
3-wire or A / B output: supply voltage 10 V DC to 30 V DC, current consumption approx. 20 mA without load
2-wire:
supply voltage 4.5 V DC to 24 V DC

Attention: The A / B output requires the use of a 4-pole round plug connector!


with integrated evaluation electronic available in the following construction types:

LABO-VHZ
: evaluation electronic with analog output or switching function incl.
FLEX-VHZ:
evaluation electronic with analog output and switching function incl.
OMNI
-VHZ: evaluation electronic with analog output, switching function and display incl.

(see below: recommended products)



 

For further details please see data sheet:

 

 

1.958,00 EUR

incl. 19 % VATexcl. shipping costs

 processing time as may be necessary - please ask!

flow transducer | VHZ-025GA150

flow transducer | VHZ-025GA150


formerly known as "Volutron"

appliance: flow, measurement
medium: water, oil
measuring range:3 l/min to 150 l/min H2O or oil
connection: G 1 internal thread, aluminium
basic data: PN 80 bar, temperature of medium -25°C to +80°C,
optionally -25°C to +120°C (2-wire model DN 10-25)
electrical data:gearwheel volumeter,
3-wire or A / B output: supply voltage 10 V DC to 30 V DC, current consumption approx. 20 mA without load
2-wire:
supply voltage 4.5 V DC to 24 V DC

Attention: The A / B output requires the use of a 4-pole round plug connector!


with integrated evaluation electronic available in the following construction types:

LABO-VHZ
: evaluation electronic with analog output or switching function incl.
FLEX-VHZ:
evaluation electronic with analog output and switching function incl.
OMNI
-VHZ: evaluation electronic with analog output, switching function and display incl.

(see below: recommended products)



 

For further details please see data sheet:

 

 

3.462,00 EUR

incl. 19 % VATexcl. shipping costs

 processing time as may be necessary - please ask!

Recommended products

round plug connector 4-/5-pole | K...PU...

round plug connector 4-/5-pole | K...PU...

0,00 EUR

flow transducer / switch | OMNI-VHZ with VHZ-...GA/GK

flow transducer / switch | OMNI-VHZ with VHZ-...GA/GK

0,00 EUR

flow switch | LABO-VHZ-S with VHZ-...GA/GK

flow switch | LABO-VHZ-S with VHZ-...GA/GK

0,00 EUR

flow transducer | LABO-VHZ-I/U/F/C with VHZ-...GA/GK

flow transducer | LABO-VHZ-I/U/F/C with VHZ-...GA/GK

0,00 EUR

Shopping Cart

You have no articles inside your cart

Shopping Cart »

Welcome back

E-mail-address:
password:
lost password?